Parameter
Value
Factory settings
Q1 Min. height jump
0 mm ... 2,147.48 mm
OD2000-
030
/
050
: 0.50 mm
OD2000-
245
/
350
/
700
: 10.00 mm
Q1 Max. Height jump
0 mm ... 2,147.48 mm
OD2000-
030
/
050
: 2.00 mm
OD2000-
245
/
350
/
700
: 100.00 mm
Q1 Jump direction
Positive
Negative
Both
Both
Q1 Cycle offset
1 ... 10,000
50
Q1 Switch point logic
High-active
Low-active
High-active
Q1 Timer mode
Off
Switch-on delay
Switch-off delay
Switch-on/off delay
Pulse (one shot)
Off
Q1 Timer setup
1 ms ... 30,000 ms
1 ms
Q1 Hysteresis
0 mm ... 2,147.48 mm
OD2000-
030
: 0.1 mm
OD2000-
050
: 0.2 mm
OD2000-
245
: 0.5 mm
OD2000-
350
: 1 mm
OD2000-
700
: 1.5 mm
7.4.3.7.1
Min. / max. height change
The
Min. height jump
and
Max. height jump
parameters define the smallest and largest dif‐
ference between the current measured value and the comparison value in millimeters.
The two measured values must differ by this amount for there to be an edge height
change. The function only takes into account the difference between two measured
values and is independent of the absolute distance of the object.
7.4.3.7.2
Change direction
The
Jump direction
parameter defines the direction in which measured value jumps are
detected.
•
Positive
: Only changes in measured values within the set limits which result in
larger distances are detected (description applies to factory setting).
•
Negative
: Only changes in measured values within the set limits which result in
smaller distances are detected (description applies to factory setting).
•
Both
: All changes in measured values within the set limits are detected.
7.4.3.7.3
Cycle offset
The
cycle offset
parameter specifies which previous measured value is compared with
the value currently measured.
OPERATION
7
8026231//2021-11-17 | SICK
O P E R A T I N G I N S T R U C T I O N S | OD2000
37