Device type
OD2000-030
OD2000-050
OD2000-245
OD2000-350
OD2000-700
Light sender
Laser, red
Visible red light
Laser class
Laser class 1 (IEC 60825-1:2014, EN
60825-1:2014)
7)
Laser class 2 (IEC 60825-1:2014, EN 60825-1:2014)
8)
Complies with 21 CFR 1040.10 and 1040.11 except for conformance with IEC 60825-1 Ed. 3, as
described in document Laser Notice No. 56 dated 8 May 2019.
Typical light spot size
Ø 50 µm (30 mm) Ø 70 µm (50 mm) Ø 500 µm
(245 mm)
Ø 600 µm
(350 mm)
Ø 1 mm (700 mm)
Additional function
Measured value recording functions and evaluation functions, adjustable average filter and median
filter, switching functions: Single point SP1 (DtO) / window SP1, SP2 (window or ObSB) / teachable
digital output, invertible digital output, teachable analog output, invertible analog output, switchable
analog output (mA / V), multifunction input: Sender off / hold functions / deactivated, switch off
display, operating button lock, display can be rotated 180°, alarm function, edge height jump, timer
mode (switch-on and switch-off delay, pulse)
1)
6% ... 90% reflectance; with standard settings.
2)
Measurement to 60% reflectance (ceramic, white).
3)
Average value setting: 512
Median: 31
Measuring frequency: 5 kHz
In the middle of the measuring range
For static measurement.
4)
At T = 25 °C, under constant general conditions.
5)
Observe min. warm-up time of 30 minutes.
6)
Dependent on the set averaging or sensitivity.
7)
Visible, wavelength: 655 nm, max. power: 0.39 mW, max. pulse power: 0,39 mW, max. pulse duration: 5 ms.
8)
Visible, wavelength: 655 nm, max. power: 1 mW, max. pulse power: 1 mW, max. pulse duration: 5 ms.
10.3
Interfaces
Device type
OD2000-030
OD2000-050
OD2000-245
OD2000-350
OD2000-700
IO-Link
✓
, IO-Link V1.1
Function: Process data, configuration, diagnostics, data storage
Data transmission rate: 230.4 kBit/s (COM3), process data length 6 bytes, minimum cycle time
1 ms
Digital input
In
1
1)
Digital output
Number: 2
2)
Type: Push-pull / PNP/NPN, selectable
Analog output
Quantity: 1
Type: Current output / voltage output
Function: Selectable
Current: 4 mA ... 20 mA, ≤ 300
W
Voltage: 0 V ... 10 V, > 10 k
W
Resolution: 16 bit
1)
Can be used as Sender off, trigger for hold functions or deactivated.
2)
PNP/PP: HIGH = U
V
> 13.5 V / LOW = U
V
< 8 V.
NPN: HIGH = U
V
< 8 V / LOW = U
V
> 13.5 V.
10.4
Ambient data
Device type
OD2000-030
OD2000-050
OD2000-245
OD2000-350
OD2000-700
Ambient operating
temperature
-10 °C ... +50 °C
1)
Storage temperature
-20 °C ... +60 °C
TECHNICAL DATA
10
8026231//2021-11-17 | SICK
O P E R A T I N G I N S T R U C T I O N S | OD2000
51
Subject to change without notice