ANNEX
9
213
8017768/12AX/2019-05-31|SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S | TIC
Change NTP Configuration
Ectn.Tems.TemsManagerCmd.exe <connection info> /ntp=127.0.0.1,ch.pool.ntp.org
Changes the list of NTP servers.
Parameters
Arguments
Default
Ntp
Comma separated list (no spaces!) of NTP servers.
If no NTP server is specified, the NTP client is deactivated.
Required
Timeout
Number of seconds to wait for the completion of this operation
20
Name
Description
ERRORLEVEL
success
The NTP configuration was successfully changed.
0
Connection Failure
Timeout, network interruption, …
100
Argument Failure
The argument was not a valid list of NTP servers.
101
Not Ready
TEMS Recorder isn’t in state “Not Configured”
102
Failure
One of the steps of the process failed. More details in the error console.
103
Change IP Configuration through TCP
Ectn.Tems.TemsManagerCmd.exe <connection info> /ip=127.0.0.1
[ /mask=255.255.255.0 ]
[ /gateway=127.0.0.1 ]
[ /dns=127.0.0.1,128.0.0.1 ]
Changes the IP configuration on the TEMS Recorder.
Parameters
Arguments
Default
IP
New IP (v4) address of the TEMS Recorder
Required
Mask
Subnet mask of the TEMS Recorder
Default Subnet Mask for IP
address
Gateway
IP address of the default gateway.
No gateway
Dns
Comma separated list of IP addresses of DNS servers.
No DNS servers
Timeout
Number of seconds to wait for the completion of this operation
300
Name
Description
ERRORLEVEL
success
The IP configuration was successfully changed.
0
Connection Failure
Timeout, network interruption, …
110
Argument Failure
One of the arguments was not valid IP address (v4)
111
Not Ready
TEMS Recorder isn’t in state “Not Configured”
112
Failure
One of the steps of the process failed. More details in the error console.
113
Change IP Configuration to DHCP through TCP
Ectn.Tems.TemsManagerCmd.exe <connection info> /ip
Makes the TEMS Recorder get its configuration from
Parameters
Arguments
Default
IP
No arguments
Name
Description
ERRORLEVEL
success
The IP configuration was successfully changed.
0
Connection Failure
Timeout, network interruption, …
110
Argument Failure
One of the arguments was not valid IP address (v4)
111
Not Ready
TEMS Recorder isn’t in state “Not Configured”
112
Failure
One of the steps of the process failed. More details in the error console.
113