9
ANNEX
212
8017768/12AX/2019-05-31|SICK
O P E R A T I N G I N S T R U C T I O N S | TIC
Subject to change without notice
Firmware update
Ectn.Tems.TemsManagerCmd.exe <connection info> /update=D:\Firmware.temsUpdate
Uploads and applies a firmware update to the TEMS Recorder.
Parameters
Arguments
Default
Update
File with the update
Required
Timeout
Number of seconds to wait for the completion of this operation
300
Updatepassword
Special password that should be used during updates from older versions of Tems
Recorder (<2.1.1)
-
Name
Description
ERRORLEVEL
success
The firmware update was successfully applied.
0
Connection Failure
Timeout, network interruption, …
70
Input Read Failure
The update file did not exist or couldn’t be accessed
71
Not Ready
TEMS Recorder isn’t in state “Not Configured”
72
Failure
One of the steps of the update process failed. More details in the error console.
73
Serial Number Change
Ectn.Tems.TemsManagerCmd.exe <connection info> /serial=12344567
Changes the serial number of the TEMS Recorder. This is only available in combination with an OEM Image.
Parameters
Arguments
Default
Serial
8-digit serial number of the TEMS Recorder (usually the serial number of the IPC)
Required
Timeout
Number of seconds to wait for the completion of this operation
300
Name
Description
ERRORLEVEL
success
The serial number change was successfully applied.
0
Connection Failure
Timeout, network interruption, …
80
Argument Failure
The serial number wasn’t in the required format.
81
Not Ready
TEMS Recorder isn’t in state “Not Configured”
82
Failure
One of the steps of the process failed. More details in the error console.
83
Already Set
Serial number was already set and cannot be changed again.
84
Set Clock
Ectn.Tems.TemsManagerCmd.exe <connection info> /time=2013-04-28T10:10:10Z
Sets the clock on the TEMS Recorder to the specified time.
Parameters
Arguments
Default
Time
Date and time in XML format.
Required
Timeout
Number of seconds to wait for the completion of this operation
20
Name
Description
ERRORLEVEL
success
The time was successfully set.
0
Connection Failure
Timeout, network interruption, …
90
Argument Failure
The argument was not a valid date/time value.
91
Not Ready
TEMS Recorder isn’t in state “Not Configured”
92
Failure
One of the steps of the process failed. More details in the error console.
93