Technical specifications
Minimum
Typical
Maximum
Contact outputs
Contact load
Volt-free relay contacts
2)
2 N/O, 1 N/C
10 mA / 24 V DC
Single output 4 A
max. total current
over all contact
outputs 6 A
230 V AC /
300 V DC
Usage category
AC-15: U
e
= 230 V, I
e
= 3 A
DC-13: U
e
= 24 V, I
e
= 2.5 A
Fuses F1, F2, F3
4 A slow-blow
Fuse F4
4 A slow-blow
Ambient conditions:
Ambient operating
temperature
Storage
temperature
Air humidity
(non-dewing)
0 °C
–25 °C
15 %
+55 °C
+70 °C
95 %
Dimensions
(L x W x H)
260 x 159 x 148 mm
3
Vibration resistance
For notes on the vibration resistance, see chapter 4.3
Weight
5 kg
2)
Relay with positively guided contacts. Relay contacts are isolated from each other by a 3 mm base isolation
(VDE 0160, VDE 0110) (mechanical life expectancy 10
7
switching cycles, electronic life expectancy
10
5
switching cycles).