![SICK LCUR1-411 Operating Instructions Manual Download Page 35](http://html1.mh-extra.com/html/sick/lcur1-411/lcur1-411_operating-instructions-manual_1264567035.webp)
Operating instructions
Chapter
5
LCUR1411
8011281/TF99/2013-02-28
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
35
Electrical installation
Designation on
LVS300
Terminal no. of the
LVS300
Terminal no. of the
LCUR1-411
Function
L
1
19 (at 230 V AC)
Voltage supply
23 (at 24 V DC)
N
2
20 (at 230 V AC)
Voltage supply
22 (at 24 V DC)
PE
PE
21
Earth conductor
Contact NC
11
18
Normally closed
circuit with fuse
Contact NC
9
17
Contact NO
7
12
Normally open
circuit with fuse
Contact NO
22
13
Contact NO
20
14
Normally open
circuit with fuse
Contact NO
24
15
Selector switch
14
2
Operating mode
switching
Selector switch
13
3
Protective operation
Selector switch
5
4
single break PSDI
mode
Selector switch
18
5
double break PSDI
mode
MCC IN
4
11
Machine contact
circuit
MCC OUT
3
10
Machine contact
circuit
EDM IN
6
8
External device
monitoring (only if
used previously)
EDM OUT
8
9
External device
monitoring (only if
used previously)
RESET
17
6
RESET (only if used
previously)
RESET
19
7
RESET (only if used
previously)