Electrical installation
Designation on AGS Terminal no. on the
AGS with hard-
wired connection
Terminal no. of the
LCUR1-411
Function
L
B1
20
(at 230/115 V AC)
Voltage supply with
230/115 V
N
B3
19
(at 230/115 V AC)
Voltage supply with
230/115 V
PE
PE
21
Earth conductor
+24 V
A1
23
Voltage supply with
24 V DC
0 V
A2
22
Voltage supply with
24 V
Contact NC
D3
18
Normally closed
circuit with fuse
Contact NC
D4
17
Contact NO
D1
15
Normally open
circuit with fuse
Contact NO
D2
14
Contact NO
D5
12
Normally open
circuit with fuse
Contact NO
D6
13
MCC OUT
C3
10
Machine contact
circuit
MCC IN
C7
11
Machine contact
circuit
Selector switch
C3
2
Operating mode
selector switch
Selector switch
C2
3
Single break PSDI
mode
Selector switch
C1
4
Double break PSDI
mode
EDM OUT
C3
8
External device
monitoring (only if
used previously)
EDM IN
C4
9
External device
monitoring (only if
used previously)
RESET
C6
7
Implementation via
CDS with C4000
RESET
C10
6
Implementation via
CDS with C4000