Table 62: Type name defining values
Defining value
Offset
Value
RID
083h
Resource name
0
"TYPECODE"
Data size
1
18
Read access level
2
0
Write access level
3
15
Time overrun
4
70
Data type
5
0Bh - string
Mandatory
yes
It should be noted that to read the whole code designation requires up to three "long
message" transactions, as a "long message" can only contain 8 bytes of data.
When accessing offset basis, the OFF ADD characteristic gives the first character of the
type name to be returned in the "long message".
Table 63: Read type name.
Transaction
Register
P
C_BUFFER0
P
C_BUFFER1
P
C_BUFFER2
P
C_BUFFER3
P
C_BUFFER4
P
C_BUFFER5
P
C_BUFFER6
P
C_BUFFER7
P
C_ADD_H
P
C_ADD_L
P
C_OFF_H
P
C_OFF_L
P
C_C
TR
L
Write
7C
83
00
00
01
Wait for FREL = 1
Read
Characters 1 to 8 of the type name
Write
7C
83
00
08
01
Wait for FREL = 1
Read
Characters 9 to 16 of the type name
Write
74
83
00
10
01
Wait for FREL = 1
Read
Characters
17 to 18 of
the
type name
8.4.5
Serial number
This resource indicates the serial number of the encoder. The serial number is stored in
ASCII format with a maximum length of 10 characters. Unallocated characters are
stored with the ASCII code 00h.
Direct read access to serial number returns the defining values:
Table 64: Serial number defining values
Defining value
Offset
Value
RID
084h
Resource name
0
"SERIALNO"
Data size
1
10
Read access level
2
0
Write access level
3
15
Time overrun
4
70
8
MOTOR FEEDBACK SYSTEM RESOURCES
96
T E C H N I C A L I N F O R M A T I O N | HIPERFACE DSL
®
8017595/ZTW6/2018-01-15 | SICK