All errors are recorded with time information, and several process and condition values
from the time at which the error occurred.
Error protocol entries are each stored in 16 bytes.
The values for the error protocol are given in the following format:
Table 105: Error protocol entries definition
Byte
Value
Description
15
00 to FFh
Error code (see
14
00 to FFh
Additional error code
13/12
0
Reserved
11/10
0 to 65535
Rotation speed in min
-1
during the error
9/8
0 to 65535
Internal supply voltage in mV during the error
7/6
0 to 65535
LED current in 0.1 mA during the error
5/4
-2730 to 10000 Temperature in 0.1 °C during the error
3 to 0
0 to
4294967295
Error time information (operating time or real-time stamp)
All error protocol entries are stored sequentially and are accessible by giving the individ‐
ual values for the offset address.
To give a complete error entry, two "long message" transactions must be carried out as
a message can only contain 8 bytes.
NOTE
It should be noted that the highest offset address that can be given depends on the
maximum number of error protocol entries for the particular product.
Table 106: Offset selection for the error protocol
Offset value Length of the
message
Return values
00 00h
8
Number of stored error messages
00 01h
8
First part of the most recently occurring error
01 01h
8
Second part of the most recently occurring error
00 02h
8
First part of the error protocol entry no. 2
01 02h
8
Second part of the error protocol entry no. 2
…
8
…
00 xxh
8
First part of the oldest error protocol entry
01 xxh
8
Second part of the oldest error protocol entry
The higher value offset byte indicates whether the first part of the error message (00h)
or the second part (01h) will be given.
The lower value offset byte indicates the desired error number.
Table 107: Reading the error protocol entries
Transaction
Register
P
C_BUFFER0
P
C_BUFFER1
P
C_BUFFER2
P
C_BUFFER3
P
C_BUFFER4
P
C_BUFFER5
P
C_BUFFER6
P
C_BUFFER7
P
C_ADD_H
P
C_ADD_L
P
C_OFF_H
P
C_OFF_L
P
C_C
TR
L
Write
7C
CC
00
01
01
Wait for FREL = 1
MOTOR FEEDBACK SYSTEM RESOURCES
8
8017595/ZTW6/2018-01-15 | SICK
T E C H N I C A L I N F O R M A T I O N | HIPERFACE DSL
®
109