Defining value
Offset
Value
Data size
1
0
Read access level
2
15
Write access level
3
0
Time overrun
4
150
Data type
5
01h - empty
Mandatory
yes
An indirect write access to this resource is required to trigger a reset or a shut-down of
the DSL motor feedback system. The offset value allows selection of the desired func‐
tion:
Table 117: Function selection
Value
Definition
0
Motor feedback system reset
1
Motor feedback system shut-down
In case of a reset, the firmware of the encoder is reset by initializing the encoder the
same way as at switch-on (see
). Following a reset command, no report is
returned. In case of a shut-down, the firmware of the encoder discontinues all commu‐
nication and enters into an endless loop state. The encoder can be taken out from this
state only by a power cycle. In both cases, all encoder operation relevant data are saved
(e.g. lifetime information, usage histograms).
NOTE
It should be noted that in case of a reset, the initializing time of the encoder as well as
the maximum resource time overrun need to be taken into account. This means, that
the encoder will start communicating only after this time has passed.
NOTE
It should be noted that after shut-down, the encoder no longer reacts to any command
until it has been switched off and on again.
NOTE
It should be noted that the shut-down function can be used to reliably store all lifetime
and usage histogram data before a planned shut-down.
Table 118: Reset write command.
Transaction
Register
P
C_BUFFER0
P
C_BUFFER1
P
C_BUFFER2
P
C_BUFFER3
P
C_BUFFER4
P
C_BUFFER5
P
C_BUFFER6
P
C_BUFFER7
P
C_ADD_H
P
C_ADD_L
P
C_OFF_H
P
C_OFF_L
P
C_C
TR
L
Write
11
00
00
00
01
Wait for FREL = 1
NOTE
This funtion must be finalized by a reset of the encoder (RID 100h).
MOTOR FEEDBACK SYSTEM RESOURCES
8
8017595/ZTW6/2018-01-15 | SICK
T E C H N I C A L I N F O R M A T I O N | HIPERFACE DSL
®
115
Subject to change without notice