Defining value
Offset
Value
Write access level
3
15
Time overrun
4
70
Data type
5
04h – 16 Bit, unsigned
Mandatory
no
The value of the supply voltage is stored as an unsigned 16 bit value. The supply volt‐
age units are 1 mV.
The supply voltage value is given in the following format:
Table 88: Supply voltage definition
Byte
Value
Description
1/0
0 to 65535
Current encoder supply voltage in mV
For this resource, access to the offset basis is not meaningful as the resource data can
be read using a "long message" transaction.
Table 89: Reading the supply voltage
Transaction
Register
P
C_BUFFER0
P
C_BUFFER1
P
C_BUFFER2
P
C_BUFFER3
P
C_BUFFER4
P
C_BUFFER5
P
C_BUFFER6
P
C_BUFFER7
P
C_ADD_H
P
C_ADD_L
P
C_OFF_H
P
C_OFF_L
P
C_C
TR
L
Write
54
C5
00
00
01
Wait for FREL = 1
Read
Supply volt‐
age
8.5.7
Rotation speed range
This resource indicates the permitted maximum shaft rotation speed for rotary DSL
motor feedback systems given in the product data sheet.
Direct read access to rotation speed range returns the defining values:
Table 90: Rotation speed range defining values
Defining value
Offset
Value
RID
0C6h
Resource name
0
"SPEEDRNG"
Data size
1
2
Read access level
2
0
Write access level
3
15
Time overrun
4
70
Data type
5
04h – 16 Bit, unsigned
Mandatory
no
The rotation speed range value is stored as a 16 bit unsigned value. The rotation speed
value units are 1 rotation per minute (min
-1
).
It should be noted that the current rotation speed value is given as a process value in
the "process data channel" (see
).
The rotation speed range value is given in the following format:
8
MOTOR FEEDBACK SYSTEM RESOURCES
104
T E C H N I C A L I N F O R M A T I O N | HIPERFACE DSL
®
8017595/ZTW6/2018-01-15 | SICK
Subject to change without notice