In general, simple I/Os can carry out one of the following functions:
Table 176: Functions of simple I/Os
Direction
Signal type
Example
Input
Digital
Switch
Output
Digital
Braking control
Input
Analog
Temperature sensor
The model name, number and measurement characteristics of simple I/Os for any
product variant are specified in the product data sheet. For analog inputs, this also lists
the data format and the units of the values measured.
Signals for digital I/Os are specified as follows:
Table 177: Definition of access simple I/Os
Byte
Value
Description
3
00h
01h
02h to FFh
Set to 0 (output) / Value = 0 (input)
Set to 1 (output) / Value = 1 (input)
Reserved
0 to 2
Reserved
The offset value gives the I/O number to be accessed. It should be noted that the num‐
ber of I/Os and the associated I/O numbers are specified in the product data sheet.
Table 178: Offset value for access simple I/Os
Offset value
Description
0 to 127
I/O number
Table 179: "Simple access I/Os" (here: Set digital output with I/O number #0)
Transaction
Register
P
C_BUFFER0
P
C_BUFFER1
P
C_BUFFER2
P
C_BUFFER3
P
C_BUFFER4
P
C_BUFFER5
P
C_BUFFER6
P
C_BUFFER7
P
C_ADD_H
P
C_ADD_L
P
C_OFF_H
P
C_OFF_L
P
C_C
TR
L
Write
00
00
00
01
00
00
00
00
3A
00
00
00
01
Wait for FREL = 1
8.11.2
Manage simple I/Os
This resource enables access to the management functions for simple I/Os connected
to the motor feedback system.
Direct read access to manage simple I/Os returns the defining values:
Table 180: Manage simple I/Os defining values
Defining value
Offset
Value
RID
201h
Resource name
0
"MANAGEIO"
Data size
1
4
Read access level
2
0
Write access level
3
2
Time overrun
4
90
Data type
5
14h – 4 byte structure
Mandatory
no
8
MOTOR FEEDBACK SYSTEM RESOURCES
134
T E C H N I C A L I N F O R M A T I O N | HIPERFACE DSL
®
8017595/ZTW6/2018-01-15 | SICK
Subject to change without notice