Table 91: Rotation speed range definition
Byte
Value
Description
1/0
0 to 65535
Maximum permitted rotation speed of the encoder in
min
-1
For this resource, access to the offset basis is not meaningful as the resource data can
be read using a "long message" transaction.
Table 92: Reading the rotation speed range
Transaction
Register
P
C_BUFFER0
P
C_BUFFER1
P
C_BUFFER2
P
C_BUFFER3
P
C_BUFFER4
P
C_BUFFER5
P
C_BUFFER6
P
C_BUFFER7
P
C_ADD_H
P
C_ADD_L
P
C_OFF_H
P
C_OFF_L
P
C_C
TR
L
Write
54
C6
00
00
01
Wait for FREL = 1
Read
Max. rota‐
tion speed
8.5.8
Rotation speed
This resource indicates the shaft rotation speed of a rotary DSL motor feedback sys‐
tem. The rotation speed is measured once per second.
If the measured shaft rotation speed is outside either one of the range limits, an error
is indicated (see
, error group 3, error number 3).
Direct read access to rotation speed returns the defining values:
Table 93: Rotation speed defining values
Defining value
Offset
Value
RID
0C7h
Resource name
0
"SPEED"
Data size
1
2
Read access level
2
0
Write access level
3
15
Time overrun
4
70
Data type
5
04h – 16 Bit, unsigned
Mandatory
no
The rotation speed value is stored as a 16 bit unsigned value. The rotation speed value
units are 1 rotation per minute (min
-1
).
It should be noted that the rotation speed value is given synchronously with the DSL
measurements trigger signal as a process value in the "process data channel" (see
). Process data
The rotation speed value is given in the following format:
Table 94: Rotation speed definition
Byte
Value
Description
1/0
0 to 65535
Current rotation speed of the encoder in min
-1
For this resource, access to the offset basis is not meaningful as the resource data can
be read using a "long message" transaction.
MOTOR FEEDBACK SYSTEM RESOURCES
8
8017595/ZTW6/2018-01-15 | SICK
T E C H N I C A L I N F O R M A T I O N | HIPERFACE DSL
®
105
Subject to change without notice