Defining value
Offset
Value
Data size
1
0
Read access level
2
15
Write access level
3
0
Time overrun
4
90
Data type
5
01h - empty
Mandatory
no
The incrementation is carried out using a write command to this resource that contains
no data (length of the long message = 0).
Table 149: Command to increment the counter
Transaction
Register
P
C_BUFFER0
P
C_BUFFER1
P
C_BUFFER2
P
C_BUFFER3
P
C_BUFFER4
P
C_BUFFER5
P
C_BUFFER6
P
C_BUFFER7
P
C_ADD_H
P
C_ADD_L
P
C_OFF_H
P
C_OFF_L
P
C_C
TR
L
Write
11
21
00
00
01
Wait for FREL = 1
8.9.3
Reset counter
This resource carries out a reset of the user-defined 32 bit counter. Direct read access
to reset counter returns the defining values:
Table 150: Reset counter defining values
Defining value
Offset
Value
RID
122h
Resource name
0
"RESETCNT"
Data size
1
0
Read access level
2
15
Write access level
3
1
Time overrun
4
105
Data type
5
01h - empty
Mandatory
no
The reset is carried out using a write command to this resource that contains no data
(length of the long message = 0).
Table 151: Command to reset the counter
Transaction
Register
P
C_BUFFER0
P
C_BUFFER1
P
C_BUFFER2
P
C_BUFFER3
P
C_BUFFER4
P
C_BUFFER5
P
C_BUFFER6
P
C_BUFFER7
P
C_ADD_H
P
C_ADD_L
P
C_OFF_H
P
C_OFF_L
P
C_C
TR
L
Write
11
22
00
00
01
Wait for FREL = 1
Read
00
00
MOTOR FEEDBACK SYSTEM RESOURCES
8
8017595/ZTW6/2018-01-15 | SICK
T E C H N I C A L I N F O R M A T I O N | HIPERFACE DSL
®
125
Subject to change without notice