SVS-1010/880/770 Transducer Options
Model #
Beam Angles
Type
Hole Size
250/50/200ST-CX
45º @ 50kHz
11º @ 200kHz
Plastic transom mount w/
depth, spd, temp.
N/A
1700/50/200T-CX
45º @ 50kHz
11º @ 200kHz
Bronze thru hull depth &
temp.
7/8"
500/50/200ST-CX
45º @ 50kHz
11º @ 200kHz
Bronze thru hull depth,
speed, & temperature
2"
P319/50/200T-ES
45º @ 50kHz
12º @ 200kHz
Plastic thru-hull flush mount
with temp
2"
B-60-0 - CX
(for 0º to 7º hull dead
rise)
45º @ 50kHz
12º @ 200kHz
Bronze thru Hull, Tilted
Element Flush Mount, Depth
& Temperature Only
2.375"
B-60-12 - CX
(for 8º to 15º hull dead
rise)
45º @ 50kHz
12º @ 200kHz
Bronze thru Hull, Tilted
Element Flush Mount, Depth
& Temperature Only
2.375"
B-60-20 - CX
(for 16º to 24º hull dead
rise)
45º @ 50kHz
12º @ 200kHz
Bronze thru Hull, Tilted
Element Flush Mount, Depth
& Temperature Only
2.375"
810-15
15ft Transducer Extension Cable
810-30
30ft Transducer Extension Cable
Digital A Cable
Adapter Cable for use with All Dual Freq. CVS-106 Versions
*All SVS Transducers come with a Conxall (Model #CX-128) 8 pin Conn. On the end of the
transducer cable
Summary of Contents for SVS-1010
Page 1: ...1 SVS 880 1010 OPERATION MANUAL...
Page 11: ...11 SVS 1010 series Flush Mounting SVS 770 880 series Flush Mounting...
Page 29: ...29 2 Specification of the connectors...
Page 32: ...32 3 3 Navigation Data page 3 3 1 Navigation Data Type1 3 3 2 Navigation Data Type2...
Page 43: ...43 Fig 1 6 3...
Page 55: ...55 2 9 Sorting MENU User data WPT List MENU Sorting the order of WPT s on the list...
Page 67: ...67 The maximum range of Correction Offset is 5nm...
Page 80: ...80 2 2 Detail Choose the AIS target and press ENTER 2 3 Goto Choose the AIS target and press...
Page 85: ...85...
Page 95: ...95...
Page 103: ...103...
Page 117: ...117...