9/20/17, 8*58 AM
Shure Publications | User Guides | ULX-D Dual and Quad Z16-20
Page 43 of 96
http://pubs.shure.com/guide/ULXD-DQ/en-US
details.
Note: Networked receivers must all be within the same frequency
band.
Networked Receivers
1. Turn on all receivers.
2. Conduct a group scan on the first receiver to find
available frequencies in each group: SCAN > GROUP
SCAN .
3. Press ENTER to accept the group number and
automatically assign the next best channel to each
receiver on the network. The receiver LEDs will flash
when a frequency has been assigned.
4. Turn on a transmitter and sync to the receiver.
Important! Leave the transmitter on and repeat this
step for each additional system.
Non-networked Receivers
1. Turn on all receivers.
2. Conduct a group scan on the first receiver to find
available frequencies in each group: SCAN > SCAN >
GROUP
SCAN > SCAN
3. When the scan is complete, use the control wheel to
scroll through each group. Press ENTER to select a
group that has enough available frequencies for all
channels in the system.
4. Sync a transmitter to each receiver channel.
Important! Leave all transmitters on use the following steps to set
up additional receiver channels:
1. Set each additional receiver channel to the same
group as the first receiver: RADIO > G:
2. Conduct a channel scan to find available frequencies
within the group: SCAN > SCAN > CHANNEL
SCAN
> SCAN
3. When the scan is complete, press ENTER to assign