AR-M350 SIMULATIONS 10-18
<List of set values>
<List of display values>
Note: Never execute this simulation with toner in the toner hopper.
If executed, excessive toner will enter the developing section,
causing an overtoner trouble. Be sure to remove the toner motor
from the toner hopper before execution.
<List of set values>
<List of set values>
Main code 9
9-1
Purpose
Operation test, check
Function (Content)
Used to check the operation under load
(clutches and solenoids) in the duplex section
and their control circuits.
Section
Duplex
Item
Operation
Operation/Procedure Select with 10 digit key pad.
1
ADMEN1(ADU motor 1 control signal)
2
ADMEN2(ADU motor 2 control signal)
3
DGS(ADU gate solenoid)
9-2
Purpose
Operation test, check
Function (Content)
Used to check the sensors and detectors in the
duplex section and their control circuits.
Section
Duplex
Item
Operation
Operation/Procedure The display is highlighted when detected.
ADUSET
ADU installation detection
DSW_D
ADU cabinet open detection
AINPD
ADU paper entry detection
APOD
ADU paper exit detection
APPD1
ADU paper detection 1
APPD2
ADU paper detection 2
1
SIMULATION 9-1
ADU OUTPUT CHECK EXECUTING...
1. ADMEN1
2. ADMEN2
3. DGS
1
SIMULATION 9-1
ADU OUTPUT CHECK. SELECT 1-3, AND PRESS START.
1. ADMEN1
2. ADMEN2
3. DGS
Press [START] key.
Press [CUSTOM SETTING] key.
SIMULATION 9-2
ADU SENSOR CHECK.
AINPD
APOD
APPD1
APPD2
ADUSET
DSW_D
Main code 10
Purpose
Operation test, check
Function (Content)
Used to check the operation of the toner motor
and its control circuit.
Section
Process
(OPC drum/developing/transfer/cleaning)/
Developing toner
Item
Operation
Operation/Procedure Select with 10 digit key pad. The toner motor
rotates for 10sec.
1
Toner motor rotation start
2
Cancel (The display returns to the main code entry menu.)
Main code 13
Purpose
Cancel (incase of a trouble)
Function (Content)
Used to cancel the self diag “U1” trouble.
(Only when FAX is installed.)
Section
Item
Trouble
Operation/Procedure Select with 10 digit key pad.
1
After canceling U1 trouble, the display returns to the main code
entry menu.
2
Without canceling a trouble, the display returns to the main
code entry menu.
2
SIMULATION 10
TONER MOTOR ACTIVATION. EXECUTING...
1
SIMULATION 10
TONER MOTOR ACTIVATION.
ARE YOU SURE ?
1. YES
2. NO
Press [START] key.
Press [CUSTOM SETTING] key.
Or after 10sec execution
SIMULATION 13
U1 TROUBLE CANCELLATION.
ARE YOU SURE ?
1. YES
2. NO
1
, !"#$%&