AR-M350 SIMULATIONS 10-17
<List of set values>
<List of set values>
<List of set values>
8-2
Purpose
Adjustment
Function (Content)
Used to check and adjust the main charger grid
voltage in each print mode and its control circuit.
Section
Process
(OPC drum, developing, transfer, cleaning)
Item
Operation/Procedure Enter the output value to be adjusted with
10 digit key pad. The current set value is
highlighted at the right of each item.
After entering the value with 10 digit key pad,
press START key.
The output is made for 30sec at the set value.
Then the output is stopped.
Default
Set range
1
Auto mode
645
200 ~ 900
2
Text mode
3
Text/Photo mode
4
Photo mode
5
Printer mode
6
Fax mode
8-6
Purpose
Adjustment
Function (Content)
Used to check and adjust the transfer charger
current and its control circuit.
Section
Process
(OPC drum, developing, transfer, cleaning)
Item
Operation/Procedure Enter the output value to be adjusted with
10 digit key pad. The current set value is
highlighted at the right of each item.
After entering the value with 10 digit key pad,
press START key.
The output is made for 30sec at the set value.
Then the output is stopped.
1
SIMULATION 8-2
MAIN GRID SETTING. INPUT VALUE, AND PRESS START.
1. AUTO (200-900)
500
SIMULATION 8-2
MAIN GRID SETTING. EXECUTING...
1 : AUTO
500
SIMULATION 8-2
MAIN GRID SETTING. SELECT 1- 6, AND PRESS START.
1. AUTO
500
2. CHARACTER
500
3. MIX
500
4. PHOTO
500
5. PRINTER
500
6. FAX
500
Or after 30sec output
Press [START] key.
Press [CUSTOM SETTING] key.
Press [START] key.
Press [CUSTOM SETTING] key.
Default
Set range
1 Cassette/manual paper feed
45PPM
267
0 ~ 620
35PPM
220
2 Paper feed from ADU
45PPM
310
35PPM
267
8-17
Purpose
Operation test, check
Function (Content)
Used to set and check the transfer roller output.
Section
Process
(OPC drum, developing, transfer, cleaning)
Item
Operation
Operation/Procedure Enter the output value to be adjusted with
10 digit key pad. The current set value is
highlighted at the right of each item.
After entering the value with 10 digit key pad,
press START key.
The output is made for 30sec at the set value.
Then the output is stopped.
Default
Set range
1
SHV front surface
160(45PPM)
120(35PPM)
0 ~ 375
2
SHV back surface
3
THV-output
780
0 ~1250
1
SIMULATION 8-6
THV+SETTING. INPUT VALUE, AND PRESS START.
1. FRONT(0-620)
140
SIMULATION 8-6
THV+SETTING. EXECUTING...
1. FRONT
140
SIMULATION 8-6
THV+SETTING. SELECT 1-2, AND PRESS START.
1. FRONT
140
2. BACK
140
Or after 30sec output
Press [START] key.
Press [CUSTOM SETTING] key.
Press [START] key.
Press [CUSTOM SETTING] key.
1
SIMULATION 8-17
TRANSFER ROLLER SETTING. INPUT VALUE, AND PRESS START.
1. FRONT (0-375)
500
SIMULATION 8-17
TRANSFER ROLLER SETTING. EXECUTING...
1. FRONT (0-375)
500
SIMULATION 8-17
TRANSFER ROLLER SETTING. SELECT 1-3, AND PRESS START.
1. SHV FRONT
500
2. SHV BACK
500
3. THV-
500
Or after 30sec output
Press [START] key.
Press [CUSTOM SETTING] key.
Press [START] key.
Press [CUSTOM SETTING] key.
+ !"#$%&