AR-M350 SIMULATIONS 10-55
*
This adjustment is performed only when the width detection volume
is replaced.
Normally use SIM 53-7 for input.
<List of set values>
Main code 53
53-6
Purpose
Adjustment
Function (Content)
Used to adjust the DSPF width detection level.
Section
SPF/DSPF
Item
Operation
Operation/Procedure Adjust the machine SPF document tray size
adjustment.
1) Extend the guide to MAX. position, select 1,
and press START.
When COMPLETE is displayed,
press CUSTOM SETTING to return to the
initial screen.
2) Move the guide to A4R position, select 2,
and press START.
When COMPLETE is displayed,
press CUSTOM SETTING to return to the
initial screen.
3) Move the guide to A5R position, select 3,
and press START.
When COMPLETE is displayed,
press CUSTOM SETTING to return to the
initial screen.
4) Move the guide to MIN. position, select 4,
and press START.
When COMPLETE is displayed,
the adjustment is completed.
If ERROR is displayed in procedures 1) - 4),
repeat the adjustment again.
SIMULATION 53-6
SPF TRAY ADJUSTMENT. SELECT 1-4, AND PRESS START.
1. MAX. POSITION
2. POSITION 1
3. POSITION 2
4. MIN. POSITION
1
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
MAX. POSITION ... COMPLETE (or "ERROR")
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
POSITION 2 ... COMPLETE (or "ERROR")
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
POSITION 1 ... COMPLETE (or "ERROR")
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
MIN. POSITION ... COMPLETE (or "ERROR")
Select 1, and
press [START] key.
Select 2, and
press [START] key.
Select 3, and
press [START] key.
Select 4, and
press [START] key.
Press [CUSTOME SETTING] key.
Press [CUSTOME SETTING] key.
Press [CUSTOME SETTING] key.
Press [CUSTOME SETTING] key.
53-7
Purpose
Adjustment, setup, operation data output, check
(display, print)
Function (Content)
Used to enter the adjustment value of SPF width
detection.
Section
DSPF
Item
Operation
Operation/Procedure Enter the adjustment value (indicated on the
back of SPF) of SPF document tray size.
Initial value
Range
1
Max. width
66
0 - 1023
2
Adjustment point 1
456
3
Adjustment point 2
713
4
Min. width
791
1
SIMULATION 53-7
SPF TRAY ADJUSTMENT (MANUAL). INPUT VALUE 0-1023, AND
PRESS START.
1. MAX. POSITION
66
SIMULATION 53-7
SPF TRAY ADJUSTMENT (MANUAL). SELECT 1-4, AND PRESS START.
1. MAX. POSITION:
66
2. POSITION 1:
456
3. POSITION 2:
713
4. MIN. POSITION:
791
Press [CUSTOM SETTING] key.
Press [START] key.
** !" #$%&'