AR-M350 SIMULATIONS 10-16
<List of set values>
7-8
Purpose
Setup
Function (Content)
Used to set Enable/Disable of warm-up time
display.
Section
Item
Operation
Operation/Procedure The warm-up time is displayed in the unit of
second.
SIMULATION 7-8
WARM UP TIME DISPLAY.
ARE YOU SURE?
1. YES
2. NO
1
SIMULATION 7-8
WARM UP TIME DISPLAY. WARMING UP,PLEASE WAIT.
(UNIT:sec)
30
SIMULATION 7-8
WARM UP TIME DISPLAY. WARM UP COMPLETED.
(UNIT:sec)
60
Press [START] key to start measuring. Press [CUSTOM SETTING] key to stop.
Warm-up ends.
Press [CUSTOM SETTING] key.
Main code 8
8-1
Purpose
Adjustment
Function (Content)
Used to check and adjust the developing bias
voltage in each print mode and its control circuit.
Section
Process
(OPC drum, developing, transfer, cleaning)
Item
Operation/Procedure
Enter the output value to be adjusted with
the 10 digit key pad. The current set value is
highlighted at the right of each item.
After entering the value with the 10-digit key
pad press the START key. The output is made
for 30 sec at the set value.
Then the output is stopped.
Default
Set range
1
Auto mode
485
0 ~745
2
Text mode
3
Text/Photo mode
4
Photo mode
5
Printer mode
6
Fax mode
7
Reverse developing bias voltage
150
0 ~255
1
SIMULATION 8-1
DV BIAS SETTING. INPUT VALUE, AND PRESS START.
1 : AUTO (0-745)
500
SIMULATION 8-1
DV BIAS SETTING. EXECUTING...
1 : AUTO
500
SIMULATION 8-1
DV BIAS SETTING. SELECT 1-7, AND PRESS START.
1.AUTO
500
2.CHARACTER
500
3.MIX
500
34.PHOTO
500
5.PRINTER
500
6.FAX
500
7.PLUS
500
Or after 30sec output
Press [START] key.
Press [CUSTOM SETTING] key.
Press [START] key.
Press [CUSTOM SETTING] key.
* !"#$%&