AR-M350 SIMULATIONS 10-3
22
11
Used to check the use frequency of FAX. (send/receive)
(Only when FAX is installed.)
Adjustment, setup,
operation data output,
check (display)
FAX
Data
12
Used to check the misfeed position and the number of misfeed
at that position. (If the number of misfeed is considerably great,
the machine must be repaired.)
Adjustment, setup,
operation data output,
check (display)
DSPF
Trouble
Misfeed
13
Used to display the process cartridge data.
Adjustment, setup,
operation data output,
check (display)
Counter
19
Used to display the scanner mode counter.
Adjustment, setup,
operation data output,
check (display)
Counter
24
1
Used to clear the misfeed counter, misfeed history, trouble
counter, and trouble history. (After completion of maintenance,
these counters must be cleared.)
Data clear
Counter
2
Used to clear the number of use (print quantity) of each paper
feed section.
Data clear
Paper feed
Counter
3
Used to clear the number of use of the staple, ADF, RADF, SPF,
DSPF, and the scanner (reading) unit.
Data clear
Counter
4
Used to reset the maintenance counter.
Data clear
Counter
5
Used to reset the developer counter.
(The developer counter of the DV unit installed is reset.)
Data clear
Process (OPC drum,
developing, transfer,
cleaning)
Counter
Developer
(DV unit)
6
Used to reset the copy counter.
Data clear
Counter
Copy
7
Used to clear the OPC drum counter and the toner cartridge
counter. (Perform when the OPC drum is replaced.)
Data clear
Process (OPC drum,
developing, transfer,
cleaning)
Counter
OPC drum
9
Used to clear the printer print counter. (After completion of
maintenance, this counter must be cleared.)
Data clear
Printer
Counter
Printer
10
Used to clear the FAX counter. (After completion of
maintenance, this counter must be cleared.)
(Only when FAX is installed.)
Data clear
FAX
Counter
11
Used to reset the drum rotation time, toner motor rotation time,
and developer rotation time counters.
The developer counter of the DV unit installed is reset.
Data clear
Process (OPC drum,
developing, transfer,
cleaning)
Counter
Developer
(DV unit)
15
Used to clear each counter in the scanner mode.
Data clear
Counter
25
1
Used to check the operations of the main drive section
(excluding the scanner (reading) section) and the toner density
sensor. (The toner density sensor output can be monitored.)
Operation test, check
Drive
Operation
2
Used to initialize the toner density when replacing developer.
(Auto adjustment)
Setup
Process (OPC drum,
developing, transfer,
cleaning)
26
3
Used to set the specification mode of the auditor. Setup must
be made according to the use condition of the auditor.
Setup
Auditor
Spec
5
Used to set the count mode of the total counter and the
maintenance counter.
Setup
Spec
Counter
6
Used to set the specification according to the destination.
Setup
Spec
Destination
10
Used to set the trial mode of the network scanner.
Setup
Operation
18
Used to set Enable/Disable of toner save operation.
(This simulation is enabled only in Japan and UK versions.
(Depends on SIM 26-6 (Destination) setup).
For the other destinations, user program P22 allows to make
the similar setup.)
Setup
Spec
Operation
mode
(Common
operation)
30
Used to set the operation mode conforming to the CE mark
(Europe standards).
(For flickers when driving the fusing heater lamp.)
Setup
Spec
Operation
mode
(Common
operation)
35
Used to set whether the trouble history of SIM 22-4 is displayed
as one-time trouble or continuous troubles when two or more
number of a same trouble occurred.
Setup
Spec
38
Used to stop printing when developer life is expired.
Setup
Other
Operation
Code
Function (Content)
Purpose
Section
Item
Main Sub
!"#$%&