AR-M350 SIMULATIONS 10-47
<List of set values 1>
<List of display values 1>
<List of set values 2>
*
Above + 10 becomes the duplex mode (DD), making duplex copy.
<List of set values 3>
<List of display values>
Main code 48
48-1
Purpose
Adjustment
Function (Content)
Used to adjust the copy magnification ratio
(main scan direction, sub scan direction).
Section
Scanner (reading)
Item
Picture quality
Operation/Procedure Perform the magnification ratio correction.
1) The current set value is highlighted on the
right of each item. In this screen, be sure to
select "1: COPY START." (Set value: 1)
2) Enter the correction value with 10 digit key
pad.
Press P to store the set value.
(Default 50, set range 0 - 99)
3) The greater the set value is, the greater the
correction is.
1 step : 0.1% adjustment
4) Press START to start copying and store the
set value. (Display value: 1)
5) Select the paper feed tray. (Set value : 2)
6) Set the scan magnification ratio.
(Set value: 3)
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 0-9, AND PRESS START.
0. TRAY SELECT
1. COPY START
2. MAGNIFICATION
3. CCD(MAIN)
4. CCD(SUB)
5. SPF(SUB)
6. CIS(MAIN)
2
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. INPUT VALUE 0-99, AND PRESS START.
3. CCD(MAIN)
50
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 1-15, AND PRESS START.
(FEED TRAY)
1. TRAY1 2. TRAY2 3. TRAY3 4. TRAY4
5. BPT
(ABOVE +10 : DUPLEX MODE)
1
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. NOW COPYING.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT.
(MAGNIFICATION)
INPUT 25-400(%)
100
50
100
1
50
50
50
Press [CUSTOM SETTING] key.
Select other than 0 - 2,
and press [START] key.
Select 1, and
press [START] key.
Select 2, and
press [START] key.
Select 0, and
press [START] key.
Press [START] key.
Press [START] key or
press [CUSTOME SETTING] key.
Press [START] key or
press [CUSTOME SETTING] key.
Press [CUSTOM SETTING] key.
Or copying is terminated.
0
Paper feed tray selection
1
Copy start (Default)
2
Print magnification ratio
3
Main scan magnification ratio (CCD)
4
Sub scan magnification ratio (CCD)
5
SPF surface magnification ratio (sub scan)
6
SPF back magnification ratio (CIS main scan)
Normal display
NOW COPYING
ERROR display
Door open
DOOR OPEN.
Jam
JAM
Paper empty
PAPER EMPTY.
1
TRAY1
2
TRAY2
3
TRAY3
4
TRAY4
5
Manual feed
Set range
25 - 400%
48-5
Purpose
Adjustment
Function (Content)
Used to adjust the exposure motor speed.
Section
Scanner (reading)
Item
Picture quality
Operation/Procedure 1) The current set value is displayed on the right
of each item.
2) Set the exposure level with 10 digit key pad.
3) Press START to store the set value.
(Default 50, set range 0 - 99)
0
Mirror motor (220mm/sec)
1
Mirror motor (168.7mm)
2
Mirror motor (110mm/sec)
3
Mirror motor (55mm/sec)
4
SPF motor (220mm/sec)
5
SPF motor (110mm/sec)
SIMULATION 48-5
MOTOR SPEED ADJUSTMENT. SELECT 0-5, AND PRESS START.
0. MIR(220)
1. MIR(169)
2. MIR(110)
3. MIR(55)
4. SPF(220)
5. SPF(110)
0
SIMULATION 48-5
SCAN MOTOR SPEED ADJUSTMENT. INPUT VALUE 0-99, AND PRESS
START.
0. MIR(220)
50
50
50
50
50
50
50
Press [START] key or
[CUSTOM SETTING] key.
Select 0 -5 and
press [START] key.
!" #$%&'