AR-M350 SIMULATIONS 10-58
<Set values>
<List of set values>
<Set value>
(1 count : 0.5 mm)
Main code 63
63-1
Purpose
Adjustment, setup, operation data output, check
(display, print)
Function (Content)
Used to check the shading correction result.
(The shading correction result is displayed.)
Section
Scanner (exposure)
Item
Operation
Operation/Procedure The latest shading data are displayed.
CCD data
Values
Description
ODD GAIN
Pixel gain adjustment value
EVEN GAIN
Pixel gain adjustment value
ODD MAX
Pixel MAX
ODD MIN
Pixel MIN
ODD AVE
Od pixel average
EVEN MAX
Even pixel MAX
EVEN MIN
Even pixel MIN
EVEN AVE
Even pixel average
ODD OFFSET
Black offset
EVEN OFFSET
Even offset
ODD DEV
Odd standard deviation
EVEN DEV
Even standard deviation
CIS data : Only when DSPF installed
Values
Description
GAIN
Gain adjustment value
MAX
Pixel MAX
MIN
Pixel MIN
AVE
Pixel average
OFFSET
Black offset
DEV
Standard deviation
SIMULATION 63-1
SHADING DATA DISPLAY.
(CCD)
ODD GAIN:
ODD OFFSET:
ODD MAX:
ODD MIN.:
ODD AVE.:
ODD DEV.:
EVEN GAIN:
EVEN OFFSET:
EVEN MAX:
EVEN MIN.:
EVEN AVE.:
EVEN DEV.:
(CIS)
GAIN:
OFFSET:
OFFSET:
MIN.:
AVE.:
DEV:
128
255
255
255
128
255
255
255
128
255
2
2
255
0
255
0
255
0
0
63-2
Purpose
Adjustment, setup, operation data output, check
(display, print)
Function (Content)
Used to execute shading.
Section
Scanner (exposure)
Item
Operation
Operation/Procedure Execute shading. During shading,
EXECUTING is displayed.
When shading is completed, COMPLETED is
displayed.
1
OC analog data correction and shading correction data making
2
DSPF analog level correction and shading correction data
making
3
Execution of CCD data taking test
63-7
Purpose
Adjustment
Function (Content)
Used to adjust the white plate scan start position
in shading white correction.
Section
Scanner (exposure)
Item
Operation
Operation/Procedure Adjust the white plate scan start position in
shading white correction. Enter the adjustment
value and press START to store it.
Initial value
Range
1
CCD scan
6
1-16
SIMULATION 63-2
SHADING EXECUTION.SELECT1-3, AND PRESS START.
1. OC SHADING
2. DSPF SHADING
3. CCD TEST SHADING
1
1
1
SIMULATION 63-2
SHADING EXECUTING...
1. OC SHADING
SIMULATION 63-2
SHADING COMPLETED.
1. OC SHADING
Press [START] key.
After completion
Press [CUSTOM SETTING] key to stop.
SIMULATION 63-7
SHADING POSITION ADJUSTMENT. PRESS START.
1. CCD
1
0
SIMULATION 63-7
SHADING POSITION ADJUSTMENT INPUT VALUE 1-16, AND PRESS
START.
1. CCD
0
Press [START] key.
Press [CUSTOM SETTING] key
or [START] key.
*( !" #$%&'