AL-2020/2035/2040/2050/2060 FAX SOFT SWITCH 12 - 2
2. Soft switch list
• When outside the set range, the default value is automatically set.
• Never change the soft switch setup which are inhibited to use.
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
S
W
1
1
Image quality priority
selection
Bit No.
1
2
Normal
0
Refer to User program
“RESO.PRIORITY”.
When a value outside
the set range is set,
the initial value is set.
Normal
0
0
2
Fine
0
1
0
Super fine
1
0
3
Inhibited to use
0
4
Auto/Manual default setup 1: Manual reception
0: Automatic reception
Automatic
reception
0
Manual reception can
be set only when
external telephone is
connected.
5
Send request protection
1: Not protected
0: Protected
Protected
0
Refer to User program
“SECURITY
SELECTION”.
6
Inhibited to use
0
7
0
8
0
S
W
2
1
Inhibited to use
0
2
0
3
0
4
0
5
Remote selection number
setup
Binary input
5
0 Refer to User program
“REMOTE
RECEPTION #”.
When a value outside
the set range is set,
the initial value is set.
6
Bit No.
Set range
5
6
7
8
0 to 9
1
7
0
8
1
S
W
3
1
Density default setup
Bit No.
1
2
3
4
5
Medium
0 When a value outside
the set range is set,
the initial value is set.
2
Light
1
0
0
0
0
0
3
Medium
0
0
1
0
0
1
4
Dark
0
0
0
0
1
0
5
0
6
Inhibited to use
1
7
Size specification
Bit No.
7
8
Conforms to the
machine
information.
0
When set to
conformity to the
machine information, if
machine information is
uncertain, set to
centimeter size.
Centimeter size
0
0
Conforms to the machine
information.
0
1
8
Inch size
1
0
1
Conforms to the machine
information.
1
1
S
W
4
1
Recall interval in
communication error
Binary input
1min
0
Refer to User program
“RECALL INTERVAL
(LINE ERROR)”.
When a value outside
the set range is set,
the initial value is set.
For the New Zealand
models, tough it is set
to 0, recall is
performed in an
interval of 1min.
Bit No.
Set range
1
2
3
4
1 to 15min
0: Recall immediately after
cutting the line
2
0
3
0
4
1
5
Recall interval in busy
Binary input
3min
0 Refer to User program
“RECALL INTERVAL
(BUSY)”.
When a value outside
the set range is set,
the initial value is set.
6
Bit No.
Set range
5
6
7
8
1 to 15min
0
7
1
8
1
Summary of Contents for AL-2020
Page 217: ...Memo ...