AL-2020/2035/2040/2050/2060 FAX SOFT SWITCH 12 - 5
S
W
15
1
Busy tone detection time
(Lower limit)
1: 350ms
0: 250ms
250ms
0
2
Busy tone detection time
(Upper limit)
1: 650ms
0: 750ms
750ms
0
3
Busy tone detection time
(Lower limit 2)
1: 150ms
0: Follows SW15-1.
150ms
1
4
Signal send level
Binary input
–11dBm
0 When a value outside
the set range is set,
the initial value is set.
5
Bit No.
Set range
4
5
6
7
8
0 (0dBm) to 26 (–26dBm)
1
6
0
7
1
8
1
S
W
16
1
Modem speed (V.33 mode
or less)
Bit No.
1
2
3
4
V.17 14.4kbps
1
V.27 2400bps
0
0
0
0
V.29 9600bps
0
0
0
1
2
V.27 4800bps
0
0
1
0
0
V.29 7200bps
0
0
1
1
V.33 14.4kbps
0
1
0
0
3
V.33 12.0kbps
0
1
1
0
0
V.17 9600bps
1
0
0
1
V.17 12.0kbps
1
0
1
0
4
V.17 7200bps
1
0
1
1
0
V.17 14.4kbps
Others
5
Modem speed in reception
fixed
Bit No.
5
6
No fixing
0
No fixing
0
0
V.29-9600BPS
0
1
6
V.27ter-4800BPS
1
0
0
V.17-14400BPS
1
1
7
Inhibited to use
0
8
0
S
W
17
1
Inhibited to use
0
2
MH fixed (Except for SG3) 1: Yes
0: No (depending on the
other party’s machine)
No
0
3
ECM MMR mode (Except
for SG3)
1: Yes
0: No
Yes
1
4
ECM JBIG mode (Except
for SG3)
1: Yes
0: No
Yes
1
5
Inhibited to use
0
6
MH fixed (in SG3)
1: Yes
0: No (depending on the
other party’s machine)
No
0
7
ECM MMR mode (in SG3) 1: Yes
0: No
Yes
1
8
ECM JBIG mode (in SG3) 1: Yes
0: No
Yes
1
S
W
18
1
Inhibited to use
1
2
1
3
0
4
1
5
0
6
0
7
0
8
0
S
W
19
1
Inhibited to use
0
2
1
3
0
4
0
5
0
6
Recording table automatic
print
1: Yes
0: No
No
0
Refer to User program
“AUTO LISTING”.
7
Inhibited to use
0
8
0
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
Summary of Contents for AL-2020
Page 217: ...Memo ...