AL-2020/2035/2040/2050/2060 FAX SOFT SWITCH 12 - 30
SW78 No.2–No.8 Print magnification ratio adjustment
(main scan)
Used to set the main scan magnification ratio in print.
By binary input, setting can be made in the range of 0 – ±12.7% in
0.1% increments.
Default: 0%
SW79 No.1 Print magnification ratio adjustment
(sub scan) flag
Used to set the sub scan magnification ratio in print.
Bit 1 indicates plus or minus of the magnification ratio.
Default: 0 (+)
SW79 No.2–No.8 Print magnification ratio adjustment
(sub scan)
Used to set the sub scan magnification ratio in print.
By binary input, setting can be made in the range of 0 – ±12.7% in
0.1% increments.
Default: 0%
SW80 No.1–No.8 Destination information
Used to set country code.
SW81 No.1–No.8 Language information
Used to set language.
SW82 No.1–No.4 OC scan size default setting
Used to set OC scan default size.
Default: 0 0 1 1 (A4)
SW82 No.5–No.8 Inhibited to use
SW83 No.1, No.2 Inhibited to use
SW83 No.3–No.8 Speaker sound volume setting pattern
number
Used to set sound volume pattern of communication end and scan
end.
Default: 1
SW84 No.1–No.8 Inhibited to use
SW85 No.1–No.8 Inhibited to use
SW86 No.1–No.8 Inhibited to use
SW87 No.1–No.8 Inhibited to use
SW88 No.1–No.8 Inhibited to use
SW89 No.1–No.8 Inhibited to use
SW90 No.1–No.8 Inhibited to use
SW91 No.1 Symbol speed 3429 send enable in V.34 send
Used to set whether symbol speed of 3429Hz is allowed or not in
V.34 send.
Default: 1 (Enable)
SW91 No.2 Symbol speed 3200 high carrier send enable
in V.34 send
Used to set whether use of high carrier is allowed or not when sym-
bol speed of 3200Hz is selected in V.34 send.
When high/low carriers are "disable", 3200Hz cannot be selected.
Default: 1 (Enable)
SW91 No.3 Symbol speed 3200 low carrier send enable
in V.34 send
Used to set whether use of low carrier is allowed or not when symbol
speed of 3200Hz is selected in V.34 send.
When high/low carriers are "disable", 3200Hz cannot be selected.
Default: 1 (Enable)
SW91 No.4 Symbol speed 3000 high carrier send enable
in V.34 send
Used to set whether use of high carrier is allowed or not when sym-
bol speed of 3000Hz is selected in V.34 send.
When high/low carriers are "disable", 3200Hz cannot be selected.
Default: 1 (Enable)
SW91 No.5 Symbol speed 3000 low carrier send enable
in V.34 send
Used to set whether use of low carrier is allowed or not when symbol
speed of 3000Hz is selected in V.34 send.
When high/low carriers are "disable", 3200Hz cannot be selected.
Default: 1 (Enable)
SW91 No.6 Symbol speed 3429 enable in V.34
communicate
Used to set whether use of 3429Hz is allowed or not as symbol
speed in V.34 communicate.
Default: 1 (Enable)
SW91 No.7 Symbol speed 2800 enable in V.34
communicate
Used to set whether use of 2800Hz is allowed or not as symbol
speed in V.34 communicate.
Default: 1 (Enable)
SW91 No.8 Symbol speed 2743 enable in V.34
communicate
Used to set whether use of 2743Hz is allowed or not as symbol
speed in V.34 communicate.
Default: 1 (Enable)
SW92 No.1–No.8 Inhibited to use
SW93 No.1–No.8 Inhibited to use
SW94 No.1–No.8 Inhibited to use
SW95 No.1–No.8 Inhibited to use
SW96 No.1–No.8 Inhibited to use
SW97 No.1–No.8 Inhibited to use
SW98 No.1–No.8 Inhibited to use
SW99 No.1–No.8 Inhibited to use
SW100 No.1–No.8 Inhibited to use
SW101 No.1–No.4 Print effective image area sub scan
lead edge void (Back surface)
Used to set void amount in print image area.
Void amount on the lead edge in sub scan direction can be adjusted.
When the set value is increased, the margin on the lead edge is
increased.
Setting is made in binary input in the increment of 16 lines.
Default: 32 lines
SW101 No.5–No.8 Print effective image area sub scan
rear edge void (Back surface)
Void amount on the rear edge in sub scan direction can be adjusted.
When the set value is increased, the margin on the read edge is
increased.
Setting is made in binary input in the increment of 16 lines.
Default: 48 lines
SW102 No.1–No.4 Scan effective image area main scan
left edge image loss (OC)
Used to set image loss in scan image area.
Image loss on the left edge in OC main scan direction can be
adjusted. When the set value is increased, image loss is increased.
Setting is made in binary input in the increment of 24 dots.
Default: 96 dots