AL-2020/2035/2040/2050/2060 EXTERNAL VIEWS AND INTERNAL STRUCTURES 4 - 8
B. AL-2050/2060
1
3
2
9
12
11
8
10
7
6
5
4
No.
Name
Signal
Type
Function / Operation
Output
1
Scanner unit home position
sensor
MHPS
Transmission sensor
Scanner unit home position detection
"H" at home position
2
POD sensor
POD
Transmission sensor
Paper exit detection
"H" at paper pass
3
PPD2 sensor
PPD2
Transmission sensor
Paper transport detection 2
"L" at paper pass
4
Cassette detection switch
CED1
Micro-switch
Cassette installation detection
"H" at cassette insertion
5
PPD1 sensor
PPD1
Transmission sensor
Paper transport detection 1
"L" at paper pass
6
Door switch
DSW
Micro-switch
Door open/close detection
(safety switch for 24V)
1 or 0V of 24V at door open
7
Drum reset switch
DRST
Micro-switch
New drum detection switch
Instantaneously "H" at
insertion of new drum
8
Paper empty sensor
SPID
Transmission sensor
Paper entry detection
"H" paper empty
9
Paper exit sensor
SRJD
Transmission sensor
Paper exit detection
"H" paper empty
10
PD1 sensor
PD1
Micro-switch
Paper width detect (AL-2060 only)
"H" at A4 size or less
"L" at A4 size or more
11
Paper sensor
SPPD
Transmission sensor
Paper transport detection
"H" paper empty
12
Upper door open/close sensor
SCOD
Transmission sensor
Cover open/close detection
"L" open
Summary of Contents for AL-2020