AL-2020/2035/2040/2050/2060 FAX SOFT SWITCH 12 - 21
S
W
103
1
Scan effective image area
sub scan lead edge image
loss (OC)
Binary input
96 lines
0
2
Bit No.
Set range
1
2
3
4
0 to 240 line
16 lines interval
1
3
1
4
0
5
Scan effective image area
sub scan rear edge image
loss (OC)
Binary input
144 lines
1
6
Bit No.
Set range
5
6
7
8
0 to 240 line
16 lines interval
0
7
0
8
1
S
W
104
1
Scan effective image area
main scan left edge image
loss (RSPF back surface)
Binary input
96 dots
0
2
Bit No.
Set range
1
2
3
4
0 to 360 dots
in the interval of 24 dots
1
3
0
4
0
5
Scan effective image area
main scan right edge
image loss (RSPF back
surface)
Binary input
96 dots
0
6
Bit No.
Set range
5
6
7
8
0 to 360 dots
in the interval of 24 dots
1
7
0
8
0
S
W
105
1
Scan magnification ratio
adjustment (OC main
scan) flag
1: –
0: +
+
0
2
Scan magnification ratio
adjustment (OC main
scan)
Binary input
0%
0
3
Bit No.
Set range
2
3
4
5
6
7
8
0 to ±12.7%
0.1% interval
0
4
0
5
0
6
0
7
0
8
0
S
W
106
1
Scan magnification ratio
adjustment (OC sub scan)
flag
1: –
0: +
+
0
2
Scan magnification ratio
adjustment (OC sub scan)
Binary input
0%
0
3
Bit No.
Set range
2
3
4
5
6
7
8
0 to ±12.7%
0.1% interval
0
4
0
5
0
6
0
7
0
8
0
S
W
107
1
Scan magnification ratio
adjustment (RSPF back
surface main scan) flag
1: –
0: +
+
0
2
Scan magnification ratio
adjustment (RSPF back
surface main scan)
Binary input
0%
0
3
Bit No.
Set range
2
3
4
5
6
7
8
0 to ±12.7%
0.1% interval
0
4
0
5
0
6
0
7
0
8
0
S
W
108
1
Scan magnification ratio
adjustment (RSPF back
surface sub scan) flag
1: –
0: +
+
0
2
Scan magnification ratio
adjustment (RSPF back
surface sub scan)
Binary input
0%
0
3
Bit No.
Set range
2
3
4
5
6
7
8
0 to ±12.7%
0.1% interval
0
4
0
5
0
6
0
7
0
8
0
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
Summary of Contents for AL-2020
Page 217: ...Memo ...