AL-2020/2035/2040/2050/2060 FAX SOFT SWITCH 12 - 27
SW45 No.2, No.3 Sequence of year/month/day in LCD,
report, and sender record
Used to set the sequence of year/month/day in LCD, report, and
sender record.
Default: 1 0 (Day/Month/Year)
SW45 No.4 Time display format
Used to set time display format in LCD, report, and sender record.
Default: 0 (24H)
SW45 No.5–No.8 Scan effective image area main scan
right edge image loss (RSPF)
Used to set image loss of scan effective area.
Image loss on the right edge in RSPF main scan direction can be
adjusted. When the set value is increased, image loss is increased.
Setting is made in binary input in the increment of 24 dots.
Default: 96 dots
SW46 No.1 Specification of print sequence in duplex
print
Used to set the print sequence in duplex print of received data.
When set to 1, an odd-number page is printed after printing the next
even-number page. (214365...)
When set to 0, print is made in the ordinary reception order.
(123456...)
Default: 1 (Print order (214365...))
SW46 No.2 Specification of rotating direction duplex
back surface print
Used to set whether the back surface is rotated 180 degrees in
duplex print or not.
When set to 1, the back surface is rotated 180 degrees and printed.
When set to 0, the back surface is not rotated and printed.
Default: 1 (180 degrees rotation)
SW46 No.3 Priority in the day of week
Used to set which is indicated first, day or day of week, when date
format is in the sequence of day, month, and year.
When set to 1, day of week is indicated first, and then day is indi-
cated.
When set to 0, day is indicated first, and then day of week is indi-
cated.
SW46 No.4 Center No. in FAST mode
Used to set which is set as FAST center number, Service-No or
Host-Tel-No.
Default: 0 (Service-No.)
SW46 No.5 Summer time
Used to set whether summer time function is enabled or not.
When set to 1, summer time function is enabled.
When set to 0, summer time function is disabled.
Default: 1 (Allow)
SW46 No.6–No.8 PBX setting (U.K., Netherlands,
Luxembourg, Belgium: Inhibited to use)
Used to set Connect/Not Connect to PBX and to set the external line
connection method when connected to PBX.
Default: 0 0 0 (Setting OFF)
SW47 No.1 Inhibited to use
SW47 No.2 External telephone connection
Used to set whether external telephone is used or not.
This switch must be set to YES in order to use external telephone.
Default: 1 (Yes)
SW47 No.3–No.8 Inhibited to use
SW48 No.1, No.2 Tone/Pulse default setup
Used to set the dial type.
Default: 1 0 (TONE)
SW48 No.3 Telephone line menu
Used to set whether tone/pulse setting is displayed on the menu or
not.
Default: 1 (Inhibit)
SW48 No.4 Inhibited to use
SW48 No.5–No.8 Scan effective image area main scan
left edge image loss (RSPF)
Used to set image loss of scan effective area.
Image loss on the left edge in RSPF main scan direction can be
adjusted. When the set value is increased, image loss is increased.
Setting is made in binary input in the increment of 24 dots.
Default: 96 dots
SW49 No.1, No.2 Inhibited to use
SW49 No.3–No.8 Speaker sound volume pattern number
in DTMF send
Used to set sound volume pattern in DTMF send.
Default: 1
SW50 No.1, No.2 Line monitor volume
Used to set on-hook monitor volume and line volume in FAX commu-
nication.
Default: 1 0 (Medium)
SW50 No.3–No.8 Line monitor volume pattern number
Used to set line monitor volume pattern.
Default: 16
SW51 No.1–No.5 DTMF send level (High group) setup
Used to set high-group send level in DTMF signal send.
Setting is made in binary input in the increment of 1.0dBm.
Default: –6dBm
SW51 No.6 CED detection time
Used to set detection time of CED/ANSam signal for judgment of
detection.
Default: 1000ms
SW51 No.7, No.8 Busy tone detection cycle
Used to set detection cycle of pulses of busy tone for detection of
busy tone.
Default: 0 0 (2puls)
SW52 No.1, No.2 Busy tone detection level
Used to set the mini. Detection level in busy tone detection.
Default: 0 0 (–43dB)
SW52 No.3 Inhibited to use
SW52 No.4 Super G3 disabled in the last call-out of
recall in case of an error
Used to set whether Super G3 is disabled or not in the last call-out of
recall in case of a send error.
When, however, the number of recall in case of a send error is 0, this
function does not operate.
Default: 0 (Super G3 disabled)
SW52 No.5 Error process in RTN reception
Used to set whether RTN reception is judged as an error or not.
(Only in G3 mode)
When set to 1, RTN reception is not judged as an error.
When set to 0, RTN reception is judged as an error.
Default: 0 (Error)
Default: 0 (No) (U.K., Netherlands, Luxembourg, Belgium) /
1 (Yes) (Germany, Sweden, Spain, Italy, Switzerland,
Finland, Denmark, Norway, France)