Checking the parameter setting
Bus Diagnostics
The figure below gives an overwie of the communication parameters of MOVIDRIVE
®
.
64350AEN
750 Master/slave
Setting of the bus parameters
on the fieldbus option card
78x IP parameters
887 Synchronization ext. controller
888 Synchronization time
970 DPRAM synchronization
RS485
810 RS485 address
811 RS485 group address
812 RS485 timeout interval
833 Response to RS485 TIMEOUT
FIELDBUS
819 Fieldbus timeout interval
831 Response to fieldbus TIMEOUT
Bus diagnostics:
090 Fieldbus PD configuration
091 Fieldbus type
092 Fieldbus baud rate
093 Fieldbus address
System bus 1/2
881/891 SBus address 1/2
880/890 CAN profile
882/892 SBus group address 1/2
883/893 SBus timeout interval 1/2
884/894 SBus baud rate 1/2
885/895 SBus synchronizations ID 1/2
887 Synchronization ext. controller
888 Synchronization time
836/837 Response to SBus TIMEOUT 1/2
750 Master/slave
100 Setpoint source
101 Control signal source
870 Setpoint description PO1
870 Setpoint description PO1
871 Setpoint description PO2
876 PO data enable
094 PO1 setpoint [hex]
095 PO2 setpoint [hex]
096 PO3 setpoint [hex]
097 PI1 actual value [hex]
098 PI2 actual value [hex]
099 PI3 actual value [hex]
873 Actual value description PI1
874 Actual value description PI2
875 Actual value description PI3
PI1
PI2
PI3
D0
D0
Binary outputs
PO1
PO2
PO3
Binary inputs
IPOS
plus®
IPOS
plus®
Drive control
setpoint processing
889 Parameter channel 2