9
156
System Manual – MOVITRAC® 07
Parameter list
Startup
8__
Unit functions
80_
Setup
802
•
8594
Factory setting
yes
no
FACTORY SETTING
NO
DELIVERY CONDITION
803
•
8595
Parameter lock
off
on
OFF
ON
804
8596
Reset statistic
data
NO
FAULT MEMORY
81_
Serial communication
810
•
8597
RS485 address
0 ... 99
811
8598
RS-485 group
address
100 ... 199
812
8599
RS485 timeout
delay
0 ... 650 [s]
813
•
8600
SBus address
0 ... 63
814
8601
SBus group
address
0 ... 63
815
8602
SBus timeout
delay
0 ... 650 [s]
816
•
8603
SBus baud rate
0
1
2
3
125 kbaud
250 kbaud
500 kbaud
1000 kbaud
82_
Brake operation
820
•
8607
4-quadrant oper-
ation
off
on
OFF
ON
83_
Fault responses
830
•
8609
Response EXT.
FAULT
2
4
IMM. STOP/FAULT
RAPID STOP/FAULT
84_
Reset response
840
8617
Manual reset
YES
NO
86_
Modulation
860
•
8620
PWM frequency
0
1
2
3
4 kHz
8 kHz
12 kHz
16 kHz
862
•
8751
PWM fix
yes
no
YES
NO
No.
OP Index
dec.
Name
Range / factory setting
Value after startup
Display
MOVITOOLS
0
0
I