8
130
System Manual – MOVITRAC® 07
Installation instructions
Installation
Line filter
MOVITRAC
®
07 frequency inverters are equipped with an line filter as standard. They
comply with the following limit value class to EN 55011 on the line side without further
measures:
•
B: 1-phase connection
•
A: 3-phase connection
– 230 V: up to 7.5 kW
– 400/500 V: up to 11 kW
Flat-type braking
resistor BW for
size 0
Push the braking resistor in the back of the heat sink. Install the braking resistor in the
heat sink with the four screws provided.
No EMC limits are specified for interference emission in voltage supply systems without
an earthed star point (IT systems). The effectiveness of line filters is severely limited.
03164AXX
Figure 72: Installing the braking resistor BW