Application examples
Project Planning
Connection
Two indicator lamps, "Fault" and "Pressure reached"
Motor temperature monitored by TF
Use the following signals and components for pressure control:
The pressure setpoint is set in the range 0 to 100 % using the
icon.
Use Reset and Enable for controlling the machine.
The controller must detect excess pressure in the piping system by means of an addi-
tional monitoring function and must respond by taking safety precautions.
03420CXX
Figure 63: Pressure control connection with DI01 = CCW/STOP / DI02 =
Enable / DI04 = Fault reset / DI05 = TF fault / DO01-C and DO01-
NO = "Fault" / DO02 = "Pressure reached"
X10:2: Clockwise
S1: Fault
X10:3: Start/stop switch
S2: Pressure reached
X10:4: Set pressure
P: Actual pressure
X10:5: Reset button
PS: Pressure sensor
AC/DC: External power supply