System Manual – MOVITRAC® 07
115
5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Application examples
Project Planning
Without dropping
resistor
The resistance value of the external setpoint potentiometer R1 must be approx. 47 k
Ω
.
You are not allowed to connect a TF if the external setpoint potentiometer does not have
a dropping resistor.
Speed-controlled
agitator
In this application, you can control the
speed with the potentiometer of the
integrated operating panel.
Control the reset, start, stop and
speed using the integrated operating
panel. Select the
icon to operate
the agitator (activation of the manual
speed control module).
Parameters
Adapt the following parameters for the agitator:
•
Local Potentiometer Mode P122: Direction of rotation
•
Ramp t11 UP (adjustment using the
icon or parameter P130)
•
Ramp t11 DOWN (adjustment using the
icon or parameter P131)
•
Minimum speed P301
•
Maximum speed P302
•
PWM frequency P860
05324AXX
Figure 61: External setpoint potentiometer with DI01 = CW/STOP /
DI02 = CCW/STOP / DI03 = Enable / DO02 = Brake
RUN
STOP
RESET