System Manual – MOVITRAC® 07
Starting the motor
Startup
9.7
Starting the motor
Analog setpoints
The following table shows which signals must be present on terminals X10:2 ... X10:4
(DIØ1 ... DIØ5) when the "UNIPOL/FIX.SETPT" setpoint is selected (P100), in order to
operate the drive with analog setpoints.
The following travel cycle shows by way of example how you start the drive with the wir-
ing of terminals X10:2 ... X10:6 and the internal fixed setpoints.
Terminal
X10:13/14
X10:2
X10:3
X10:4
Function
Analog input
CW/STOP
CCW/STOP
Enable
/No enable
X
X
X
0
Enable and stop
X
0
0
1
Clockwise at 50 % n
max
5 V
1
0
1
Clockwise n
max
10 V
1
0
1
Counterclockwise at 50 %
n
max
5 V
0
1
1
Counterclockwise n
max
10 V
0
1
1
X = Any / 0 = Low / 1 = High
02981ADE
Figure 83: Travel cycle with internal fixed setpoints
X10:2 = CW/STOP
X10:4 = Enable/Rapid stop
X10:6 = n12/n22
X10:3 = CCW/STOP
X10:5 = n11/n21