![SEW-Eurodrive MOVITRAC 07 System Manual Download Page 151](http://html1.mh-extra.com/html/sew-eurodrive/movitrac-07/movitrac-07_system-manual_1250133151.webp)
System Manual – MOVITRAC® 07
151
9
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Parameter list
Startup
05_
Binary outputs
051
Binary output
DO01
/FAULT (factory setting)
052
Binary output
DO02
BRAKE RELEASED (factory setting)
053
Binary outputs
DO01, DO02
Binary display
07_
Unit data
070
Unit type
[Text]
071
Output rated cur-
rent
[A]
076
Firmware basic
unit
[Part number and version]
08_
Fault memory
080
•
8366
Fault t-0
Fault
code
Background information for faults which
occurred previously.
09_
Bus diagnosis
090
PD configuration
•
1 PD + PARAMETER
•
1 PD
•
2 PD + PARAMETER
•
2 PD
•
3 PD + PARAMETER
•
3 PD
094
•
8455
PO1 setpoint
[hex]
095
•
8456
PO2 setpoint
[hex]
096
•
8457
PO3 setpoint
[hex]
097
PI1 actual value
[hex]
098
PI2 actual value
[hex]
099
PI3 actual value
[hex]
1__
Setpoints/ramp generators
10_
Setpoint selection
100
•
8461
Setpoint source
1
2
4
6
7
10
11
UNIPOL/FIX.SETPT
RS485
MOTOR POT
FIX SETP+AI1
FIX SETP*AI1
SBus
Frequency input (in preparation)
101
•
8462
Control signal
source
0
1
3
4
TERMINALS
RS485
SBus
3-WIRE-CONTROL
102
•
8840
Frequency scal-
ing
Setting range 0.1 ... 10 ... 65.00 [kHz]
No.
OP Index
dec.
Name
Range / factory setting
Value after startup
Display
MOVITOOLS
0
0
I