Safety DF-760E
157
Carcinogenicity: Nickel
NTP? YES IARC? YES OSHA? NO
NICKEL has been classified by both the International Agency for Research on Cancer (IARC) and the National Toxicology Program
(NTP) as having sufficient evidence of carcinogenicity in experimental animals. In addition, IARC has determined that there is
inadequate evidence of carcinogenicity in humans (Class 2B). The American Conference of Governmental Industrial Hygienists
(ACGIH) has categorized nickel as A5 (not suspected as a human carcinogen). In evaluating NICKEL COMPOUNDS, the International
Agency for Research on Cancer (IARC) has determined that there is sufficient evidence of carcinogenicity to humans (Group 1). The
National Toxicology Program (NTP) lists only certain nickel compounds as substances which may reasonably be anticipated to be
carcinogenic. This product contains one of those nickel compounds specifically identified by NTP.
Carcinogenicity: Titanium Dioxide
NTP? NO
IARC? NO
OSHA? NO
Chronic Health Hazards:
Refer to Potential Health Effects and Carcinogenicity.
Medical Conditions Generally Aggravated by Exposure:
May aggravate existing medical conditions such as allergies, dermatitis, asthma, bronchitis or any other respiratory ailment.
NOTE: See Section 8 for Exposure Limits, Section 11 for Toxicological Information and Section 12 for Ecological Information.
SECTION 4 – FIRST AID MEASURES
In the unlikely event that the purifier media is liberated from the purifier body these health hazards may arise from inhalation, ingestion,
and or/contact with the skin and/or eyes
Eye Contact:
Immediately flush eyes with plenty of water for at least 15min. Call a physician.
Skin Contact:
Immediately wash skin with soap and plenty of water. If irritation persists, call a physician.
Inhalation:
Remove to fresh air. If breathing is difficult, oxygen should be administered by qualified personnel. Call a physician.
Ingestion:
Get medical attention! If vomiting occurs, keep head lower than hips to prevent aspiration.
SECTION 5 – FIRE-FIGHTING MEASURES
Flash Point:
Not Determined
Auto-Ignition:
Not Applicable
LEL:
Not Applicable
UEL:
Not Applicable
NFPA Hazard Classification: Nickel
Health: 1 Flammable: 2 Reactivity: 0
HMIS Hazard Classification: Nickel
Health: 2* Flammable: 2 Reactivity: 0
* Indicates the possibility of chronic health effects. See Chronic Health Hazards in Section 3 for more information.
NFPA Hazard Classification: Titanium Dioxide
Health: 0 Flammable: 0 Reactivity: 0
HMIS Hazard Classification: Titanium Dioxide
Health: 1* Flammable: 0 Reactivity: 0
* Indicates the possibility of chronic health effects. See Chronic Health Hazards in Section 3 for more information
Extinguishing Media:
Use water, carbon dioxide or foam.
Special Fire-Fighting Procedures:
Wear NIOSH/MSHA approved positive-pressure self-contained breathing apparatus and protective
clothing as specified in 29 CFR 1910.156.
Unusual Fire and Explosion Hazards:
This product will remain stable when housed in the purifier body.
When nickel is exposed air at temperatures below 175ºF (79ºC) will remain stable. At temperature above
175ºF (79ºC), oxidation will occur. Nickel when exposed to excess air and moisture, the oxidation process
Summary of Contents for NanoTrace DF-760E
Page 1: ...NanoTrace Dual Moisture Oxygen Analyzer DF 760E Instruction Manual...
Page 4: ......
Page 38: ......
Page 44: ......
Page 122: ......
Page 128: ......
Page 138: ......
Page 142: ......
Page 143: ...Service DF 760E 139...
Page 144: ...140 DF 760E...
Page 148: ......
Page 166: ......
Page 168: ......
Page 171: ...DF 760E 167...
Page 174: ...170 DF 760E Appendix A User Menu Screens Page 88 Page 91 Page 93 Page 97 Page 98 Page 99...
Page 176: ...172 DF 760E Appendix A User Menu Screens Page 110 Page 111 Page 113 Page 114 Page 115 Page 116...