88
Operations Switched PDU
Installation and Operations Manual
Setting the FTP Password:
The Set FTP Password command sets the password as required by the FTP Host.
To set the FTP password:
At the Switched CDU: prompt, type
set ftp password
, followed by the FTP password and press
Enter
.
Example
The following command sets the FTP password to Test1:
Switched CDU: set ftp password Test1<Enter>
Setting the filename to be uploaded:
The Set FTP Filename command sets the filename of the firmware file to be uploaded.
To set the FTP filename:
At the Switched CDU: prompt, type
set ftp filename
, followed by the firmware filename and press
Enter
.
Example
The following command sets the FTP filename to snb_s50a.bin:
Switched CDU: set ftp filename swcdu-v60g.bin<Enter>
Setting the directory for the file to be uploaded:
The Set FTP Directory command sets the directory for the firmware file to be uploaded.
To set the FTP directory:
At the Switched CDU: prompt, type
set ftp directory
, followed by the directory and press
Enter
.
Example
The following command sets the FTP directory to ftp://Sentry:
Switched CDU: set ftp directory ftp://sentry<Enter>
Enabling or disabling automatic updates:
The Set FTP Autoupdate command is used to enable or disable automatic firmware update support.
To enable or disable automatic updates:
At the Switched CDU: prompt, type
set ftp autoupdate
, followed by
enabled
or
disabled
and press
Enter
.
Setting the automatic update scheduled day:
The Set FTP Autoupdate Day command is used to set the day when automatic updates occur.
To set the automatic update day:
At the Switched CDU: prompt, type
set ftp autoupdate day
, followed by
a day of the week or
everyday
and press
Enter
.
Example
The following command sets the automatic update day to Sunday:
Switched CDU: set ftp autoupdate day sunday<Enter>
Setting the automatic update scheduled hour:
The Set FTP Autoupdate Hour command sets the hour of the day when automatic updates occur.
To set the automatic update hour:
At the Switched CDU: prompt, type
set ftp autoupdate hour
, followed by
an hour of the day and press
Enter
.
Examples
The following command sets the automatic update hour to 12 AM:
Switched CDU: set ftp autoupdate hour 12am<Enter>
The following command sets the automatic update hour to 3 PM:
Switched CDU: set ftp autoupdate hour 3pm<Enter>
Summary of Contents for Switched Rack PDU
Page 1: ...Switched Rack Power Distribution Unit Installation and Operations Manual Firmware Version 7 0 ...
Page 18: ......
Page 96: ......