7.2. Disassembling the dispensing tap
Before removing the bowl it is recommended to disassemble the tap; after
cleaning the tap must not be reapplied until the bowl has been correctly posi-
tioned in its seat.
Follow these instructions to disassemble the tap:
1 remove pin (F) without moving the tap lever;
4 remove the spring and top body by pushing downward with a fi nger.
2 take out the lever;
These components may be placed in a basin containing hot water (approx.
50°C); they must later be treated as described in section 7.4.
Never disassemble the tap if the product or any other liquid is
present inside the bowl.
7.3. Removing the bowl and the lid
Removal of every granita bowl is fundamental to ensure correct machine clean-
ing and sanitization.
To remove a bowl correctly proceed as follows:
1 Remove the cover and the under-cover.
3 Disassemble the piston and star geared motor.
Fig.27
Fig.23
Fig.24
Fig.25
Fig.26
Fig.28