Information

To properly use the operator it is necessary to programme the run-
ning-length and the force. 

Using the operator without these 

important adjustments may lead to damages on the garage 
door and the operator. For test-runs without a garage door 
the running-length blocks must be tightened (please refer 
to page 8 “Adjusting the running-lenth blocks”).

The programming procedure is done completely automatic with 
an automated procedure. The programming-mode needs to be 
started first - it will be indicated by the blinking operators’ light.

The quick-reference on this page shows a short summary of the 
procedure.

1.) Adjusting the running-length blocks

This step is descriped on page 8, “Adjusting the running-length 
blocks”. 

(Remark: the blocks are fixed by tightening the 

screw).

2.) Starting the programming-mode

Keep the LERN/LEARN button () pressed for 3 seconds - release 
it once the operators‘ light begins blinking. The operator is now 
running in programming-mode.

3.) Start the learning-cycle

Shortly press the LERN/LEARN button () once again. The operator 
now starts three fully automatic measurement-runs:
3.1. First the block for OPENING direction is searched for
3.. Second the operator closes the garage door with low speed 
(during this run you may also change the length of the factory 
pre-set soft-stop, as described on page 13).
3.3. The operator stops when the garage door ist closed - the 
measured running-length is now stored in the memory
3.4. The operator opens the garage door and measures the re-
quired opening-force
3.5. The operator closes the garage door and measures the re-
quired closing-force
3.6. The operator stops in closing position and remains blinking 
for a couple of seconds. 

Once all the measures values have saved in the memory the opera-
tors’ light stops blinking - now the operator is ready for use.

Procede with the programming of hand-transmitters on page 18.

Programming Running-Length and Force

Printed Circuit Board: Adjustments and Connections

Quick Reference

1.) Adjustment of blocks

The running-length blocks for 
opening and closing direction 
must be properly adjusted (please 
refer to page 8)

.) Start programming 
mode

Press the LERN/LEARN button for 
approx. 3 seconds. The operators’ 
light begins blinking - release the 
LERN/LEARN button

3.) Start the learning-cycle

Press the LERN/LEARN button 
once again shortly: the operator 
now starts three fully automatic 
measurement-runs.

The learning cycle stops after the three runs. The garage door 
is then closed and the operators’ light stops blinking. The pro-
gramming is now complete.

4.) You may now procede with chapter “Remote Control“ on 
page 18

INFORMATION: 
When the learning-cycles are made as to the procedure 
described on this page, then the operator will be pro-
grammed with the standard values for the soft-modes. 
Shall the soft-modes be changed or disabled, then please 
refer to pages 14+15.

The learning-cycle can be repeated at any time. Running 
a new learning-cycle will overwrite the old values and 
substitute them with the new ones. 

Summary of Contents for TS Akku II

Page 1: ...1V2 TS Akku II English Installation Instructions for the garage door operator This booklet must be handed over to the end user together with the user manual...

Page 2: ...on 2 Combined TEST LERN button functions Programming Running Length and Force 13 Information 1 Adjusting the running length blocks 2 Starting the programming mode 3 Start the learning cycle Quick Refe...

Page 3: ...s comply to the directives and the installation was made as to the manufacturers instructions the whole installa tion will normally be CE compliant Older Garage Doors When automating an older garage d...

Page 4: ...r according to the advises on page 3 and to the door manufacturer s manual If possible install the drive at a height of at least 2 10 m and the manual release at a height less than 1 80 m Locate the p...

Page 5: ...g situations If the garage door is higher than 2 250 mm you will need a c rail extension Two sizes of extensions are available 500mm and 1 000 mmm The operator may be extended by a maximum of 1 500mm...

Page 6: ...easure ment for the required running length When shipped the opera tor is programmed with a standard running length for factory testings If you want to run the operator for testing purposes you must f...

Page 7: ...ix the operator to the ceiling when you have made sure the C rail is running straight to the front Use the supplied bracket to fix the C rail to the ceiling pic 4 and 4a 5 Now fix the door arm to the...

Page 8: ...ck for the closing direction is now right in front of the trolley Pic 2 If not the block must be moved until it touches the trolley 4 Tighten the blocks screw to keep it in place Take care not to tigh...

Page 9: ...al opening cycle 4 Check the function of the emergency release together with a second person Stay inside the garage and close the door with the operator Let the second person open the door manually wi...

Page 10: ...batteries are shipped fully charged Usage The shelf will take two batteries The batteries may be used one after the other whilst one supplies the operator with power the other may be recharged by mea...

Page 11: ...on the status of the battery Usually it will be sufficient to leave the battery connected to the charger over night The charger is equipped with a automa tic cut off to pretend the battery from being...

Page 12: ...g advanced programming functions The LEARN button must be pressed for approx 3 sec the button can be released once the operator s light starts blinking Whilst the operator s light is blinking you can...

Page 13: ...he measured running length is now stored in the memory 3 4 The operator opens the garage door and measures the re quired opening force 3 5 The operator closes the garage door and measures the re quire...

Page 14: ...switched ON or OFF LED TEST FUNK is off pre warning is OFF LED TEST FUNK is glowing pre warning is ON 4 by shortly pressing the TEST RUN button the pre warning can be switched ON and OFF 5 after makin...

Page 15: ...or will procede with the remaining measurement runs When the operators light stops blinking all measured values are saved in the memory the BOTTOM soft stop now is in the programmed position Disabling...

Page 16: ...ong as the operators light in switched on it can therefore not be used for external remote receivers Receiver Module HF Modul Receiver Card Plug for a Seip receiver module Component Photocell without...

Page 17: ...stor The resistor on the P C B between Gnd and SLZ must therefore be removed 2 Hatch Door Contact A hatch door within the garage door can be secured with a switch when the switch is not activated e g...

Page 18: ...s instructions for programming Programming Transmitter and Receiver To use a hand transmitter it must first be registered programmed by the receiver Only one hand transmitter button can be used for on...

Page 19: ...teries run the lower the range will be Building materials of the garage In a garage made of concrete and steel you might reach a lower range than in an ordinary garage build of stone The more steel wa...

Page 20: ...pe Panasonic LC RA1212P Pre Warning Light adjustable Soft Stop in Closing Direction adjustable Net Running Length 2 640 mm Max Running Length with Extension 500 mm 4 050 mm Overall Length 3 200 mm Hei...

Page 21: ...on the electronics together with the red LED lamp on the outside of the housing With some of the messages the operators lighting will be blinking simultaneousely Messages from the red LED lamp and the...

Page 22: ...61000 3 2 2000 Limits for harmonic current emissions Grenzwerte f r Oberschwingstr me EN 61000 3 3 1995 Corrigendum 1997 A1 2001 Limitation of voltage changes voltage fluctuations and flicker in publ...

Page 23: ...other relevant provisions of the FTEG Article 3 of the R TTE Directive when used for its intended purpose bei bestimmungsgem er Verwendung den grundlegenden Anforderungen des 3 und den brigen einschl...

Page 24: ...24...

Reviews: