14
Printed Circuit Board: Adjustments and Connections
Special Functions
Readjusting the time for the internal light
The time for the internal light may be adjusted from 10 seconds to
5 minutes. The factory setting is 3 minutes.
To readjust the time procede as described below:
1. Keep the
LERN/LEARN
button pressed
for 6 seconds
.
Release
the button once the
green LED „TEST/FUNK“ turnes on
.
.
Shortly
press the
LERN/LEARN
button again.
3. The green LED „
TEST/FUNK
“ now starts
blinking at 1 second
intervalls
- each blinking increases the time by 10 seconds.
5. Once the required time is reached, press again the LERN/LEARN
button shortly. The value is then saved in the memory - the pro-
gramming is finished.
LED TEST/FUNK blinks .... times Time for light is:
6 x
1 minute
1 x
minutes
18 x
3 minutes
4 x
4 minutes
30 x
5 minutes
Setting the pre-warning ON/OFF
1. Keep the
LERN/LEARN
button pressed
for 6 seconds
.
Release
the button once the
green LED „TEST/FUNK“ turnes on
.
.
Shortly
press the
TEST/RUN
button
3. The
green LED TEST/FUNK
indicates whether the pre-warning
is switched ON or OFF:
LED TEST/FUNK is off: pre-warning is OFF
LED TEST/FUNK is glowing: pre-warning is ON
4. by
shortly pressing
the
TEST/RUN button
the pre-warning
can be switched ON and OFF
5. after making your choice shortly
press
the
LERN/LEARN
but-
ton - the setting will be saved to the operators‘ memory.
Quick Reference „Time for internal light“
1.) Keep the red LEARN
button pressed for 6
seconds
After 3 seconds the operators‘
light starts blinking, after 6
seconds the green LED „TEST“
turnes on
.) Release LEARN button
LED „TEST“ is on
3.) Shortly press LERN/
LEARN button
LED „TEST“ begins blinking at 1
second intervalls. Each
blinking adds 10 seconds to the
time (starting from zero)
4.) Press LEARN button
shortly when required time
is reached
The adjusted time will be saved in
the memory.
Quick Reference „Pre-Warning“
1.) Keep the red LEARN
button pressed for 6
seconds
After 3 seconds the operators‘
light starts blinking, after 6
seconds the green LED „TEST“
turnes on
.) Release LEARN button
LED „TEST“ is on
3.) Shortly press the black
TEST
button
LED „TEST“ indicates status:
LED on: pre-warning ON
LED off: pre-warning OFF
4.) Shortly press the
TEST
button
By pressing the TEST button the
pre-warning is switched on and
off:
LED on: pre-warning ON
LED off: pre-warning OFF
5.) Shortly press the red
LEARN button
The chosen adjustment is saved
into the memory.