Advanced Connections
Printed Circuit Board: Adjustments and Connections
Safety-Beam, Hatch-Door and Emergency Stop
(N.O.)
(with 8, kOhm
resistor)
Function
The devices on this connector are checked during the complete opening and closing procedure. When this connector is inter-
rupted, then the operator will stop immediately followed by a short reversion.
If more than one device is connected, then
they must be connected in series
. The connector can be used for the following components:
1.) Safety-Beam
Standard safety-beams are equipped with an 8,kOhm resistor. The resistor on the P.C.B. (between „Gnd“ and „SLZ“)must
therefore be removed.
.) Hatch-Door Contact
A hatch-door within the garage door can be secured with a switch - when the switch is not activated (e.g. the hatch-door
stands open) the operator will not work.
3.) Emergency Stop
The procedure to connect an emergency stop push-button is the same as for the hatch-door contact.
Opto Sensoric Components
OSE-Transmitter
OSE-Receiver
Safety-Beam
Hatch-Door
Safety-Beam and Hatch-Door
DIP-Switches
DIP-Switch No.
Function
ON
OFF
1
(
Two
Functions!)
Standard setting: ON
Function 1:
(DIP-Switch position
before and during
the learning cycle)
TOP Soft-Mode enabled/disabled
(ref. page 15)
enabled
disabled
Function 2
(DIP-Switch position
after
the learning cycle)
Force during the last 500mm before reaching closing limit
normal force
higher force
2
Standard setting: ON
Side Hinged Door
side hinged
door
tilting or sec-
tional door
3
no function
-
-