In case of a power failure the garage door can be opened by
hand. Therefore the operator first needs to be released.
When the garage door is the only entrance
It is necessary to connect the emergency release to the door‘s
handle (pic. 1) otherwise the garage cannot be accessed in a
power failure situation.
Procede as follows:
1.
Find out in which direction the door handle moves when open-
ing the door.
2.
Drill a hole in that side of the door handle which turns down-
wards.
3.
Thread the cable through the hole and fix it with the enclosed
metal-clamps. Be carefull not to put a high tension on the emer-
gency release cable - the operator then might release from the
garage-door during a normal opening cycle.
4.
Check the function of the emergency release together with a
second person. Stay inside the garage and close the door with
the operator. Let the second person open the door manually with
the door keys. If this works, the emergency-release is mounted
properly
.
Do not leave the garage and close the garage-door with the
operator before you have tested the emergency-release!
The Emergency Release
When there is a second entrance to the garage
You can use the supplied handle for the emergency release (pic.
).
Thread the emergency release cable through the handle.
Fix the metal clamps to the cable where the handle shall be
placed.
Shorten the cable below the metal clamps - the handle is now be-
ing held by the clamps.
In case of a power failure the user can now open the garage
door by releasing the operator with the handle for the emergency
release.
Installation
Pic. 1
Pic.
Summary of Contents for TS Akku II
Page 24: ...24...