background image

3

It is within legal regulation and without restriction, to use a 
Seip door operator with any garage door that has been ap-
proved for use with other certified door operators!

Directives and Regulations

The garage door operator TS Solar/TS Akku complies to the latest 
European directives and regulations. The declaration of conformity 
is enclosed at the end of these instructions.

Use of the operators

The operators were designed for the use with up-and-over doors 
(tilting and canopy-type) and sectional doors. 
All garage doors need to be maintained before automation. The 
door must be easily opened and closed by hand. A garage door 
must not be automated unless it is easy to open and close manu-
ally.

Garage Doors

In January 001 the European regulations EN1604 and EN1605 
became compulsory for garage doors. Before installing an au-
tomatic door operator it must be assured that the garage doors 
applies to these regulations (the information can be obtained from 
the manufacturers‘ declaration of confirmity). A Seip door opera-
tor may be installed to any door that complies to the regulations. 
Should a garage door not be compliant then please refer to the 
chapter „older garage doors“.

The installers declaration of conformity

No matter whether a door operator was delivered together with a 
garage door or seperately, the installer must issue a declaration of 
conformity for the complete installation.
With this declaration the installer assures, that the installation 
was made according to the instructions given by the manufactur-
ers (e.g. the installation instructions of the garage door and the 
operator). This declaration can only be issued by the installer and 
may not be issued from the manufacturer! 
If both components comply to the directives and the installation 
was made as to the manufacturers instructions the whole installa-
tion will normally be CE-compliant.

Older Garage Doors

When automating an older garage-door the TS-series will still 
comply to the regulations - through the automatic force setting 
the requested values for forces and reversion will be according to 
the regulations.
But it needs to be taken in consideration that most older garage 
doors do not meet the regulations EN 1604 and EN 1605 
- especially regarding security features. They might still have sharp 
edges bearing the danger of severe injuries - for example sectional 
doors might not have a finger protection between the sections. 
Unfortunately the entire regulations do not mention how to 
handle the automation of such an older garage door - the danger 
basically is not the automation but the construction of the door.

Therefore we strongly recommend to
- check the garage door for sharp edges bearing danger when the 
door is moving; take any necessary action to avoid the dangers 
and make the door safer
- check the doors‘ springs and readjust them if necessary
- grease or oil the pivotal points and rollers of the garage door
- check that the door may be easily used by hand

If, however, the dangers cannot be avoided we recommend to use 
the automatic pre-warning function of the operator. The opera-
tors‘ lighting will then be blinking for approx. 5 sec. before every 
movement of the garage door. People inside the garage will be 
warned before the opening and can step back from the garage 
door in time.

Instruction for the users

Please instruct the users as follows:
- Use of the hand transmitter
- Use of the emergency release in case of a power failure
- Hand over the separate „User Manual“ to the customer
- Inform the user about the Security Advises in the User Manual

Important Information for the Installer

Information and Remarks

Up-and-over door

sectional door

Summary of Contents for TS Akku II

Page 1: ...1V2 TS Akku II English Installation Instructions for the garage door operator This booklet must be handed over to the end user together with the user manual...

Page 2: ...on 2 Combined TEST LERN button functions Programming Running Length and Force 13 Information 1 Adjusting the running length blocks 2 Starting the programming mode 3 Start the learning cycle Quick Refe...

Page 3: ...s comply to the directives and the installation was made as to the manufacturers instructions the whole installa tion will normally be CE compliant Older Garage Doors When automating an older garage d...

Page 4: ...r according to the advises on page 3 and to the door manufacturer s manual If possible install the drive at a height of at least 2 10 m and the manual release at a height less than 1 80 m Locate the p...

Page 5: ...g situations If the garage door is higher than 2 250 mm you will need a c rail extension Two sizes of extensions are available 500mm and 1 000 mmm The operator may be extended by a maximum of 1 500mm...

Page 6: ...easure ment for the required running length When shipped the opera tor is programmed with a standard running length for factory testings If you want to run the operator for testing purposes you must f...

Page 7: ...ix the operator to the ceiling when you have made sure the C rail is running straight to the front Use the supplied bracket to fix the C rail to the ceiling pic 4 and 4a 5 Now fix the door arm to the...

Page 8: ...ck for the closing direction is now right in front of the trolley Pic 2 If not the block must be moved until it touches the trolley 4 Tighten the blocks screw to keep it in place Take care not to tigh...

Page 9: ...al opening cycle 4 Check the function of the emergency release together with a second person Stay inside the garage and close the door with the operator Let the second person open the door manually wi...

Page 10: ...batteries are shipped fully charged Usage The shelf will take two batteries The batteries may be used one after the other whilst one supplies the operator with power the other may be recharged by mea...

Page 11: ...on the status of the battery Usually it will be sufficient to leave the battery connected to the charger over night The charger is equipped with a automa tic cut off to pretend the battery from being...

Page 12: ...g advanced programming functions The LEARN button must be pressed for approx 3 sec the button can be released once the operator s light starts blinking Whilst the operator s light is blinking you can...

Page 13: ...he measured running length is now stored in the memory 3 4 The operator opens the garage door and measures the re quired opening force 3 5 The operator closes the garage door and measures the re quire...

Page 14: ...switched ON or OFF LED TEST FUNK is off pre warning is OFF LED TEST FUNK is glowing pre warning is ON 4 by shortly pressing the TEST RUN button the pre warning can be switched ON and OFF 5 after makin...

Page 15: ...or will procede with the remaining measurement runs When the operators light stops blinking all measured values are saved in the memory the BOTTOM soft stop now is in the programmed position Disabling...

Page 16: ...ong as the operators light in switched on it can therefore not be used for external remote receivers Receiver Module HF Modul Receiver Card Plug for a Seip receiver module Component Photocell without...

Page 17: ...stor The resistor on the P C B between Gnd and SLZ must therefore be removed 2 Hatch Door Contact A hatch door within the garage door can be secured with a switch when the switch is not activated e g...

Page 18: ...s instructions for programming Programming Transmitter and Receiver To use a hand transmitter it must first be registered programmed by the receiver Only one hand transmitter button can be used for on...

Page 19: ...teries run the lower the range will be Building materials of the garage In a garage made of concrete and steel you might reach a lower range than in an ordinary garage build of stone The more steel wa...

Page 20: ...pe Panasonic LC RA1212P Pre Warning Light adjustable Soft Stop in Closing Direction adjustable Net Running Length 2 640 mm Max Running Length with Extension 500 mm 4 050 mm Overall Length 3 200 mm Hei...

Page 21: ...on the electronics together with the red LED lamp on the outside of the housing With some of the messages the operators lighting will be blinking simultaneousely Messages from the red LED lamp and the...

Page 22: ...61000 3 2 2000 Limits for harmonic current emissions Grenzwerte f r Oberschwingstr me EN 61000 3 3 1995 Corrigendum 1997 A1 2001 Limitation of voltage changes voltage fluctuations and flicker in publ...

Page 23: ...other relevant provisions of the FTEG Article 3 of the R TTE Directive when used for its intended purpose bei bestimmungsgem er Verwendung den grundlegenden Anforderungen des 3 und den brigen einschl...

Page 24: ...24...

Reviews: