© 2014
SeaStar Solutions
Optimus Installation Manual, Rev. E
5-10
POWER STEERING PUMP
note: if wall-mounting the power steering pump:
• Pumps must be mounted upright to facilitate oil fill and purge.
• If mounting to an angled wall, use shims
to mount the pump upright. If you are
mounting to a 12° transom, use
wedge kit HA5485.
SEE MOUNDING HARDWARE
RECOMMENDATIONS
3 X FLAT
WASHER
POWER
STEERING
PUMP
Figure 5-12.
Figure 5-11.
note: if floor-mounting the power steering pump:
• Pumps must be mounted
upright to facilitate oil fill
and purge.
Figure 5-10.
DO
Protect from
elements
5°
Mount at
vertical
angle of less
than 5°