DOCS-010 Manual, SeaBotix Inc. Users, 200 Series – 18 Mar 09 - Rev B - Page 26 of 52
Example: To enter LBV 150 as user text
1. Press 5 three (3) times until the L is shown.
2. Press ENT
3. Press 2 twice (2) until the B is shown.
4. Press ENT
5. Press 8 three (3) times until the V is shown.
6. Press 0 two (2) times.
7. Press ENT
8. Press 1 one (1) time.
9. Press ENT
10. Press 5 four (4) times.
11. Press ENT
12. Press 0 one (1) time.
13. Press *
2.3.3.5
Reset to Defaults
a. Pressing the 5 key will reset the entire LBV to factory settings.
NOTE:
Resetting to defaults will erase any stored data and can result in
inaccurate sensor indications. Please contact SeaBotix Inc. prior to (or upon)
selecting this option.
2.3.4
Calibrate Menu
2.3.4.1
Tilt Indicator
a. Pressing the 1 key will calibrate the camera angle indicator on the Video
Overlay. Once pressed, the LBV will automatically rotate the camera to the
90º position and then back to the 0º position.
NOTE:
Do not calibrate the tilt function while the tilt function is reversed. If
operating with camera tilt reversed, refer to section 2.3.6.3 to return it to normal
prior to calibration.
2.3.4.2
Temperature
a. Pressing the 2 key will allow you to calibrate the temperature display on the
Video Overlay.
To adjust the displayed value to the known external temperature:
Press key 1 to increase the value
Press key 2 to decrease the value
Press key 3 to reset the value