DOCS-010 Manual, SeaBotix Inc. Users, 200 Series – 18 Mar 09 - Rev B - Page 15 of 52
1.4.3.3
Video Overlay
1. Check that the date and the time are set correctly (section 2.2.5.)
2. Calibrate the heading (section 2.2.3)
3. Check that the desired depth measurement (section 2.2.3)
4. Check that the temperature measurement is correct. Adjust if needed (section
2.2.4).
5. Input the desired User Text (section 2.2.1).
1.4.3.4
Accessories
If fitted with accessories such as a grabber, press the SELECT button to cycle through the
installed accessories. The selected accessory will display on the Video Overlay in the 2nd
line of the text (see section 2.2 for additional information regarding the Video Overlay.)
Press the
and the
keys to operate each accessory and to verify that they function
properly.
1.5
Post Dive Inspection
After each use of the LBV, take a moment to do a visual inspection of the LBV prior to
storage. It is good practice to submerge the LBV into a container of fresh water or rinse with
a fresh water hose and wipe clean.
Check the LBV for damage.
Check the thrusters for debris caught near or in the propellers.
Quickly check the LBV functions to ensure that all systems operate
correctly.
Check for lost ballast strips or weights.
1.6
Storage of System
Proper storage of the LBV will make the next use much easier and keep the LBV in good
condition.
After rinsing the LBV and wiping off any excess water, disconnect the
shackle from the pad eye and unplug all tether connectors.
Place the LBV in a carrying/shipping case. Ensure that the LBV is dry.
Disconnect all connectors from the Integrated Control Console/Surface
Power Supply.
Coil up all cables and store.
Place the OCU in a carrying/shipping case.
Place the tether in a carrying/shipping case.
Close and clamp cases for transport or storage.