1
2
3
- 24 -
- 25 -
EN
Manual programming
Programming is carried out in four steps, which are briefly
summarised here.
1.
Start manual programming
Disconnect the power supply — wait at least 20 s — and recon
-
nect the power supply.
When the electronics are booting, the LED in the sensor field
flashes red/yellow.
Do not put your hands into the sensor area during this phase!
Afterwards the LED is red for max. 7 s. During this red phase,
cover the sensor area and keep it covered. Programming mode
is started.
2.
Select function (F1 - F2)
The functions are now indicated one at a time by the flashing
yellow LED (see table).
To select a function, uncover the sensor field when the corres
-
ponding code is flashing.
3.
Set parameters
The flashing red LED shows you the currently set parameter (see
table).
By covering the sensor area again you can set the corresponding
parameter. The parameters are indicated one at a time by the
flashing red LED (see table).
To set a parameter, uncover the sensor area when the correspon
-
ding code is flashing.
4.
Start operation
After leaving the sensor field, the programming mode starts once
again with a time window of 7 seconds (red LED is on conti-
nuously).
If the sensor field is not covered during these 7 seconds, the
programming is completed. The fitting is now ready for use.
Parameters:
4 s
6 s
8 s
10 s
15 s *
20 s
30 s
40 s
60 s
120 s 180 s 240 s
Functions
F1
Flow time
(P1 - P12)
1x
2x
3x
4x
5x
6x
7x
8x
9x
10x
11x
12x
Parameters:
P1
P2
P3
F2
Stagnation flush
Off *
On, 24 h after last
use **
On, daily
every 24 h
*
*
Factory setting
** Programming example
In the pictures on pages 34 to 35, manual programming is depicted
step-by-step.
As an example it is shown how to set the
„Stagnation flush“
function
(F2) to „
On, 24 h after last use
“ (P2).
Manual programming
Operating elements for programming:
1 Sensor field
2 LED (yellow / red)
3 Sensor area
The following table provides an overview of the main programs
and the available parameters for programming the fitting manually: