112
P2.36
Override 1
Default value
10
P2.37
Override 2
Default value
20
P2.38
Override 4
Default value
40
P2.39
Override 8
Default value
80
Setting range
0~150 [%]
These parameters are enabled under speed and position control.
To use these signals, be sure to turn on "override enable."
With this setting, the speed can be changed during operation. For the weight of the override, refer to the
table below.
Override 8 Override 4 Override 2 Override 1
Traveling speed (%)
OFF
OFF
OFF
OFF
0
OFF
OFF
OFF
ON
10
OFF
OFF
ON
OFF
20
OFF
OFF
ON
ON
30
OFF
ON
OFF
OFF
40
OFF
ON
OFF
ON
50
OFF
ON
ON
OFF
60
OFF
ON
ON
ON
70
ON
OFF
OFF
OFF
80
ON
OFF
OFF
ON
90
ON
OFF
ON
OFF
100
ON
OFF
ON
ON
110
ON
ON
OFF
OFF
120
ON
ON
OFF
ON
130
ON
ON
ON
OFF
140
ON
ON
ON
ON
150
*P2.40
Internal positioning data selection
Default value
0
Setting range
0: Disable
1: Enable
Select whether the internal positioning data is enabled or disabled.
Setting “0”: Immediate value data operation over RS-485 Modbus communications.
Setting “1”: Positioning data operation with address settings AD3 to AD0