40
3.3 Control Status Display Mode
Control status display mode means the servo motor drive‟s output signal and running status.
Press key [MENU] to display [Cn-01], press [SET] to display description.
Action mode
Means servo motor drive‟s output signal and running status
Cn-01
—
PoF
[SET]
[MENU]
Ready for servo-on
PoF
Speed coincidence
Zero speed
Display
Control
mode
Name
Content
Position
control
Servo OFF
No power to motor. No drive power in servo motor
Servo ON
Servo motor is under rotatable operation
Manual operation
Being rotating is feed by manual
Pulse operation
Pulse is being inputted
Auto-operation
Being positioning operation
Homing
Being homing
Interrupt positioning Being interrupt positioning
+OT
Overrun signal of the forward direction is being detected
−OT
Overrun signal of the reverse direction is being detected."P"
and "−" display alternately
Zero speed stop
Input forced-to-stop signal to make it stop at zero speed.
LV Status
Low voltage. For more detail information, please refer to the
page regarding the under voltage
Speed
control
Servo OFF
No power to motor. No drive power in servo motor
Servo ON
Servo motor is under rotatable operation
Manual operation
Being rotating is feed by manual
+OT
Overrun signal of the forward direction is being detected
−OT
Overrun signal of the reverse direction is being detected.
Zero speed stop
Input forced-to-stop signal to let it stop at zero speed
LV Status
Low voltage. For more detail information, please refer to the
page regarding the under voltage